Configuring the
PEM with the CLI
3 Set the ISDN switch type:
set imod int rm0/slot:1/mod:1 at at*w=[switch type]
Switch type
AT&T 5ESS
Northern Telecom DMS-100
National ISDN-1
ETSI
Germany
Australia
Italy
Japan
New Zealand
Spain
Taiwan
4 Set the ISDN connection type:
set imod int rm0/slot:1/mod:1 at at*v2=5
set imod int rm0/slot:1/mod:2 at at*v2=5
You need to force a connection type for both channels (rm0/slot:1/mod:1
and rm0/slot:1/mod:2).
5 Save your changes:
set imod int rm0/slot:1/mod:1 at at&wz!
The RAS 1500 stack does not immediately recognize the removal or
substitution of PEM units.
To remove and substitute another PEM module to an existing setup, issue
the reboot command at the CLI prompt.
After the reboot process occurs, RM automatically recognizes each PEM
attached to it.
See "Accessing the CLI Locally", earlier in this chapter, to connect to the
Console Port.
Configuring the PEM with the CLI
Command
at*w=0
at*w=1
at*w=2
at*w=3
at*w=4
at*w=5
at*w=6
at*w=7
at*w=8
at*w=9
at*w=10
4-7