Load safety information The maximum permitted working load of the Flying adapter corresponds to a weight of a maximum of two V-Point or Vi-Point cabinets flown one below the other. No additional loads must be added. d&b Z5384/Z5551 Mounting instructions 1.4 en...
Weight 1.5 kg (3.5 lb) 2.2 Z5384 Intended use The d&b Z5384 VP Flying adapter must only be used in connection with d&b V-Point/Vi-Point and d&b 24S/24S-D cabinets as described in these mounting instructions. The Flying adapter can be used with the following rigging...
For this application, two additional Flying adapters are required. The attachment of the Flying adapters is carried out in the same manner as described in Þ Chapter 2.3 "Z5384 Assembly" on page 6. 1. Attach one flying adapter each to the top and bottom panels of the first (upper) cabinet.
Page 8
8. Recheck your work before lifting the assembly to its operating position. ↳ Ensure all four Locking pins are fully inserted and properly locked Joining the cabinets Shown: Hole pair 8/9, vertical splay of 5° d&b Z5384/Z5551 Mounting instructions 1.4 en...
▪ Visual inspection for deformation, cracks and corrosion of the component. ▪ Inspection for missing ball bearings and damage. ▪ Functional inspection of the release mechanism to ensure it operates properly. ▪ Regularly lubricate the Locking pins using WD-40® or a similar product. d&b Z5384/Z5551 Mounting instructions 1.4 en...
When out of use the rigging components must be disposed of in accordance with the national environmental regulations. Ensure that damaged rigging components are disposed of in a way that they cannot be used again. d&b Z5384/Z5551 Mounting instructions 1.4 en...