HollySys HT5 Series Instructions For Use Manual page 9

Metal tube flowmeter
Table of Contents

Advertisement

Product
Model
Technical
Parameters
Meter diameter
Measuring range
Range ratio
Accuracy
Mounting height
Wetted materials
Pressure Level
Connection
Ambient temperature
Medium temperature
Signal output
Power supply
Explosion levels
Protection class
Medium viscosity
Display method
Electrical connections
HT50
Standard :250mm( Particular, please consult the manufacturer )
R0(316)R1(304)RL(316L)RP(PTFE lining )
RC( Hastelloy C)RT(Ti titanium liner )
Standard : DN15~DN50
DN80~DN200
Particular: DN15~DN50
DN80~DN150 2.5~16MPa;
Jacketed pressure rating :1.6MPa ;
Standard flanges : HG/T20592-2009; Or specified by the user of any standard flanges
-40℃~120℃, Flameproof :-20℃~+40℃, Intrinsically Safe :-20℃~+40℃
Standard -40℃~+120℃; Particular -80℃~+350℃; PTFE lining ≤80℃
Two-wire4
~
20mA
switch ,8VDC power supply;
Standard :24VDC(10.8VDC~28VDC) AC type :220VAC(85~265VAC)
Intrinsically Safe :Exia II CT6 Ga
DN15~DN150
water (20°) 16~150000L/h;
air (20°0.1013MPa )0.5~5000m3/h
Standard :10:1; Particular :20:1
1.0;1.5
4.0MPa;
1.6MPa;
5~42MPa;
output;Hart
communication;Two-wire
Battery type :3.6V-9Ah lithium battery
IP65
DN15: ≤5mpa.s(H15.1~15.3)
≤30mpa.s(H15.4~15.9)
DN25:≤250mpa.s
DN50~DN150:≤300mpa.s
Scene pointer display; LCD
1/2"NPT;M20×1.5;
6
HT51
HT52 HT53
R0(316); R1(304) ; RL(316L) ;
Standard :
DN15~DN50
4.0MPa;
DN80~DN200
1.6MPa;
Particular :
DN15~DN50
5~42MPa;
DN80~DN100 2.5~25MPa;
DN150
2. 5~16MPa
sensor
Flameproof :Exd II CT6 Gb
threshold

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ht50Ht51Ht52Ht53Ht54Ht55 ... Show all

Table of Contents