HollySys HT5 Series Instructions For Use Manual

Metal tube flowmeter

Advertisement

Quick Links

HT5 series metal tube flowmeter
Instructions for use
Please read the manual before using the product

Advertisement

Table of Contents
loading

Summary of Contents for HollySys HT5 Series

  • Page 1 HT5 series metal tube flowmeter Instructions for use Please read the manual before using the product...
  • Page 2: Table Of Contents

    CONTENTS 1、Instructions........................1 Intended use.........................1 Safety instructions......................1 Copyright and data protection...................1 Technical Support......................1 2、Device description......................2 Brief description......................2 Structure principle......................2 2.3 Features..........................3 Capabilities ........................3 Technical Parameters ......................4 Model Description .......................7 Flow Meter...........................8 Indicator Type........................9 Indicators Structure and disassembly ...................11 Float damping 2.10...
  • Page 4: Intended Use

    Metal tube flowmeter 1. Terms and Conditions Intended use Metal tube flowmeter in mind, also known as variable area flowmeter (hereinafter referred to as meter).The variable area flowmeter are suitable for measuring gases, vapours and liquids.Meter can be used to measure the continuous cleaning of gases and liquids, especially for flow measurement and control of low flow, low flow rate, harsh media conditions.
  • Page 5: Technical Support

    2. Product description Description HT5 series metal tube is based on a variable area flow meter float position measurement. All-metal structure, modular design, because of its small size, small pressure loss, range ratio (10: 1), easy installation and maintenance, etc., it is widely used in various industries complex, harsh environment, low flow, low flow rates, a variety of harsh conditions of media flow measurement and process control.
  • Page 6: Structure Principle

    HT5 series metal tube flowmeter user requirements, vertical mount (HT50), progress under-mount (HT51), side into the side mount (HT52), end into the side-mounted (HT53), threaded connection type (HT54), horizontal-mounted installation (HT56R / L) and other options. Structure principle series metal tube composed of two parts: Measuring tube - magnetic couplings, sensors;...
  • Page 7: Features

    2.3 Features  Simple and practical, low-cost installation, in situ measurements without auxiliary power;  General concept of prevent explosion: explosion-proof and intrinsically safe isolation integration;  Modular design, easy maintenance, maintenance-free normal use;  A variety of flow: horizontal, down-up, up- down, side to side, a bottom side optional;...
  • Page 8: Technical Parameters

    HT5 series metal tube flowmeter Calibration function: analog output current calibration; Calibration function: You can choose from 5 to 16 points calibration; Host variable zero: zero trim function; Power-down protection: In case of power failure without loss of data; LCD backlight: LCD with backlight can be better at night or in dark light observation instruments;...
  • Page 9 Product Model HT50 HT51 HT52 HT53 Technical Parameters Meter diameter DN15~DN150 water (20°) 16~150000L/h; Measuring range air (20°0.1013MPa )0.5~5000m3/h Range ratio Standard :10:1; Particular :20:1 Accuracy 1.0;1.5 Mounting height Standard :250mm( Particular, please consult the manufacturer ) R0(316)R1(304)RL(316L)RP(PTFE lining ) Wetted materials R0(316);...
  • Page 10 HT5 series metal tube flowmeter Product Model HT54 HT55 Technical Parameters Meter diameter DN15~DN100 DN15~DN100 water(20°)16~100000L/h water(20°)16~100000L/h Measuring range air(20°0.1013MPa) air(20°0.1013MPa) 0.5~3000m3/h 0.5~3000m3/h Range ratio Standard :10:1; Particular :20:1 Accuracy 1.0;1.5 Mounting height Standard :250mm( Particular, please consult the manufacturer ) Wetted materials R0:316;R1:304;RL:316L;...
  • Page 11 Product Model HT56 Technical Parameters Meter diameter DN15~DN50 DN80~DN150 water(20°)16~25000L/h water(20°)16~150000L/h Measuring range air(20°0.1013MPa) air(20°0.1013MPa) 0.5~1000m3/h 1000~4000m3/h Range ratio Standard :10:1; Particular :20:1 Accuracy 1.0;1.5 Mounting height 250mm 250mm or 350-400mm Wetted materials R0:316;R1:304;RL:316L; R0(316); R1(304) ; RL(316L) ; Standard :DN15~DN50 4.0MPa Standard :DN80~DN150 1.6MPa Pressure Level Particular :DN15~DN50 6.3MPa...
  • Page 12: Model Description

    HT5 series metal tube flowmeter 2.6 Model Description □ \ □ \ □ \ □ \ □ \ □ EX Intrinsically safe Proof Ed Explosion Isolation 1 Local Indication (pointer) 2 24VDC, pointer, 4-20 output 3 220VAC, pointer and LCD, 4-20MA output 4 24VDC,pointer and LCD, 4-20MA output...
  • Page 13 Float Material: 1□ R0、R1、RC 2□ PTFE、RT Caliber Float size Water Standard HT50 (20℃) 0.1013MPa(abs) 20℃ The maximum pressure loss m3/h 1□ 2□ 1□ 水 空气 H15.1 H15.2 H15.3 H15.4 H15.5 H15.6 H15.7 10.0 H15.8 10.0 10.8 H15.9 16.0 H25.1 H25.2 1000 H25.3 1600...
  • Page 14 HT5 series metal tube flowmeter M4 indicator may install different modules for different functions. Indicator with LCD display variables can be set, see the specific commissioning instructions. 2.8.1 M41 Indicator(Basic type) ①------- pointer ②------- Axis system assembly ③------- Rail bracket fastening screws ④------- Rail bracket...
  • Page 15: Indicators Structure And Disassembly

    ④------- Conversion module and 24V DC power outlet ⑤------- Rail bracket ⑥------- Operation buttons ⑦------- The nameplate ⑧------- External ground screw ⑨------- Outlet connector The main function: With the sensor with, 24VDC power supply, enabling LCD and pointer, two-wire 4-20mA output (selectable Hart communication). 2.8.5 M45 Indicator ①------- pointer ②------- LCD...
  • Page 16 HT5 series metal tube flowmeter  Indicator Construction: housing cover, instrument panel, conversion module, plug the module frame rails, pointers, Axis system assembly, chassis and other components.  Loosen housing cover locking screws, unscrew the housing cover (when installed housing cover must be tightened to prevent the corrosive gas and water vapor into the device casing corrosion).
  • Page 17 Will result in these cases in the media flow meter measuring tube is very unstable, float suffered three forces can not achieve equilibrium caused by the float up and down, up and down movement of the float is transmitted by a magnetic coupling system, so do follow the motion of the pointer Axis system, ultimate expression of continuous non-stop swing pointer larger output variation margin.
  • Page 18 HT5 series metal tube flowmeter of stable operation of the instrument. Dimensions are shown. Straight pipe straight pipe PTFE lining filter PTFE lining filter Caliber DN15 DN25 DN50 DN80 DN100 DN150 Former straight pipeH1≥(mm) After the straight pipeH2≥ (mm) d(mm)...
  • Page 19 is bent into a U-shaped to provide a drip point; cable connection fittings to avoid the use of ferromagnetic materials products, the ferromagnetic material will affect the measurement; to the terminal, and then the outlet connector locking nut tightened before tightening indicator cover to ensure that housing is airtight.
  • Page 20 HT5 series metal tube flowmeter M4 type indicator can install up to two limit switches constitute M4K1 and M4K2 type indicator. Limit switch is a fork sensor, activated by the metal blade by induction semicircular pointer on. The switching point by the limit pointer to set the dial at the switch position display on the dial.
  • Page 21  Can install one or two two-wire limit switch (Strictly speaking, "initiator") SJ3, -N.  After the switch board into the slot, fan-shaped plate pointer just cut or cut out from the "initiator" recess to meet Flow rate requirements.  Must start with the transistor relay (isolating switching amplifier) or digital boards and other support to complete the switch function.
  • Page 22: Ht50/Rp

    HT5 series metal tube flowmeter 4 Dimensions 4.1 HT50 Basic type and Jacket type Dimensions Weight kg Caliber Basic Jacket DN15 DN25 DN50 DN80 15.5 DN100 DN150 4.2 HT50/RP Dimensions Caliber A mm Weight kg DN15 DN25 DN50 DN80 15.5 DN100 16.5...
  • Page 23 4.3 HT51 Dimensions Caliber A mm Weight kg DN15 DN25 DN50 DN80 15.5 DN100 16.5 4.4 HT52 Dimensions Caliber DN15 DN25 E mm H mm Weight kg Pressure Loss DN15~DN25 Caliber DN50 DN80 DN100 DN150 E mm H mm Weight kg Pressure Loss...
  • Page 24 HT5 series metal tube flowmeter DN50~DN150 4.5 HT53 Dimensions寸 Caliber DN15 DN25 E mm H mm Weight kg Pressure Loss DN15~DN25 Caliber DN50 DN80 DN100 DN150 E mm H mm Weight kg Pressure Loss DN50~DN150 4.6 HT54 Dimensions HT54 type is screwed down into the flow of the metal tube, food-type round thread DIN11851 and SMS can be used for food production instrument and pharmaceutical industries.
  • Page 25 4.7 HT55 Dimensions HT55 type for quick card mounted next entry on the flow of metal tube, the use of sanitary fittings snap-mounted instrument can be used for the production of the food industry, it can also be used for other require quick installation card installed traffic measurement place for measurement and Flow rate control.
  • Page 26: 5、 Installation

    HT5 series metal tube flowmeter 4.8 HT56 Dimensions picture 1 DN15 DN25(H=380/400mm) picture 2 DN50(H=480mm) There are three structures as shown in HT56 type, the order should specify the media flow, for example HT56R medium flows out into the left and right, HT56L medium flow to the left right out.
  • Page 27 5.1 Installation Requirements  New pipe before installing the instrument must be cleaned or purged, because the pipeline welding slag left over from the ferromagnetic particulate impurities easily adsorbed on the float, causing float stuck, the instrument does not work properly. If the meter has a bypass, it should first open the bypass operation for some time, and then turn on the meter pipe, close the bypass.
  • Page 28 HT5 series metal tube flowmeter  Upstream pipeline and downstream pipe bore should be the instrument have the same nominal size, the upstream straight pipe length should ensure that more than 5 times the flowmeter Caliber upstream and downstream straight pipe length of 250mm or more; in order to prevent pipeline expansion, mating flange must pipe axis to pair and parallel to each other;...
  • Page 29: Installation Diagram

    gaskets must be replaced. The cable must be set drip Bay, to prevent water from entering the housing. Cable interface must be tightened. If you do not wear dead plugging cables. 5.3 Installation diagram...
  • Page 30 HT5 series metal tube flowmeter...
  • Page 31: 6、Maintenance

    6 maintenance 6.1 Indicator  Indicator detected correctly premise: You must ensure that the float of flexible working properly. Care must be taken to check the fastening screw is loose, remove the base or total demolition indicator (try not to disassemble) the position can not be changed, or it may cause misalignment between the float caused by deviation indicator.
  • Page 32 HT5 series metal tube flowmeter detected and the corresponding instructions.  Output current deviation detection step instructions: Confirm pointer correctly (if there is no standard site traffic detection method is the only one float falls below the pointer points to accurately indicate the RP). And then to push the float detected indicating correspondence between the outputs.
  • Page 33 is low (eg less than 10.8VDC), or even stop the phenomenon of self-test you should first ensure power supply (or cable) Is there a problem, you can pass a single 24VDC power supply confirmation.  Meter anti-jamming measures requirements: due to the higher degree of intelligence (eg Hart communication), the instrument corresponding anti-jamming measures require a corresponding increase.
  • Page 34: Measuring Tube

    HT5 series metal tube flowmeter plate from the tank is withdrawn and then detecting the pointer is flexible. If you remove the alarm board and flexible operation, the fan-shaped plate observe pointer to cut the initiator is not a part of the tank wall stickers starting problems. You can adjust the pointer to the segment-type plate making flexible movement....
  • Page 35 of two-phase flow (liquid and vapor exist), as long as the measures to eliminate the presence of two-phase flow, can make the stable operation of the instrument.  Flowmeter at the factory by calibration, generally do not need field calibration if the pipeline flow is zero, and confirm that the float is not stuck foreign matter, while not indicating zero point, which may be due to the meter around a ferromagnetic material, make zero offset, you should adjust the installation direction and position, so that the...
  • Page 36: 7、Caliber

    HT5 series metal tube flowmeter 7 Caliber Understanding of traffic: Valve opening, pump head, Flow rate and pressure size, etc. are no absolute correspondence, can not represent the size of the flow. 7.1 Determine the correction coefficient Kx a. A user is given if the liquid volume Flow rate Qv, is calculated by the formula Ka: ...
  • Page 37        e. If the user is given gas mass Flow rate Qm, is calculated using the formula Ks:        The above formulas: ρ ------ The density of the measured medium Liquid measured medium density refers to the 20 ℃, 0.1013MPa under(g/cm )...
  • Page 38 HT5 series metal tube flowmeter Kx--- Means the correction factor B. Water and air Flow rate B. Flow rate given in the table refers to 20 ℃, normal traffic 0.1013MPa state, which allows the range of + 10% of normal flow, ie, after the calculated...
  • Page 39 Appendices Selection Specification Hangzhou Hollysys Automation System Engineering Co., Ltd. Selection Specification Contract No: Delivery Time: User Parameters The number of the same type: Bit No.: Product Model: Accuracy: Standard flanges: Pressure Level: Media Name: Medium density under standard conditions (kg/Nm Medium viscosity (mPa.s):...

This manual is also suitable for:

Ht50Ht51Ht52Ht53Ht54Ht55 ... Show all

Table of Contents