HollySys HT5 Series Instructions For Use Manual page 11

Metal tube flowmeter
Table of Contents

Advertisement

Product
Model
Technical
Parameters
Meter diameter
Measuring range
Range ratio
Accuracy
Mounting height
Wetted materials
Pressure Level
Connection
Ambient temperature
Medium temperature
Signal output
Power supply
Explosion levels
Protection class
Medium viscosity
Display method
Electrical
connections
DN15~DN50
water(20°)16~25000L/h
air(20°0.1013MPa)
0.5~1000m3/h
Standard :10:1; Particular :20:1
250mm
R0:316;R1:304;RL:316L;
Standard :DN15~DN50 4.0MPa
Particular :DN15~DN50 6.3MPa
Standard flanges :HG/T20592-2009;Or specified by the user of any standard
-40℃~120℃, Flameproof :-20℃~+40℃,Intrinsically Safe :-20℃~+40℃
Standard -40℃~+120℃; Particular -80℃~+350℃
Two-wire4 ~ 20mA output;Hart communication;Two-wire sensor threshold
switch ,8VDC power supply;
Standard :24VDC(10.8VDC~28VDC) AC type :220VAC(85~265VAC)
Intrinsically Safe :Exia II CT6 Ga
HT56
1.0;1.5
R0(316); R1(304) ; RL(316L) ;
Standard :DN80~DN150 1.6MPa
Particular :DN80~DN50 6.3MPa
flanges
Battery type :3.6V-9Ah lithium battery
Flameproof :Exd II CT6 Gb
IP65
DN15: ≤5mpa.s(H15.1~15.3)
≤30mpa.s(H15.4~15.9)
DN25: ≤250mpa.s
DN50~DN150:≤300mpa.s
Scene pointer display; LCD
1/2"NPT;M20×1.5;
8
DN80~DN150
water(20°)16~150000L/h
air(20°0.1013MPa)
1000~4000m3/h
250mm or 350-400mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ht50Ht51Ht52Ht53Ht54Ht55 ... Show all