HollySys HT5 Series Instructions For Use Manual page 19

Metal tube flowmeter
Table of Contents

Advertisement

is bent into a U-shaped to provide a drip point; cable connection fittings to avoid
the use of ferromagnetic materials products, the ferromagnetic material will affect
the measurement;
to the terminal, and then the outlet connector locking nut tightened before tightening
indicator cover to ensure that housing is airtight.

Proof products Note:
the meter pointer mark the approval label, if the intrinsically safe explosion-proof
EXiaII CT6Ga, should be based on the maximum allowable connection cable distributed
capacitance, inductance parameter selection cable, by placing in a safe place barrier
for the power meter. If it is flameproof EXdIICT6Gb should be noted that cables are
lead directly to a safe place, no points midway core wire, cable and wiring should be
connected to the lead terminals solid and reliable, without fly line phenomenon.
3.2 Conversion module wiring
Only for M42, M44, M45 type indicator. For 220V AC power supply M45 type indicator, power
lines and signal lines, respectively, the joint should enter from a different outlet.
Connection diagram is as follows:
3.3 Limit switches and wiring
When used in hazardous locations, please first check whether
16