Features - HollySys HT5 Series Instructions For Use Manual

Metal tube flowmeter
Table of Contents

Advertisement

2.3 Features


Simple and practical, low-cost installation, in situ measurements without
auxiliary power;

General concept of prevent explosion: explosion-proof and intrinsically safe
isolation integration;

Modular design, easy maintenance, maintenance-free normal use;

A variety of flow: horizontal, down-up, up- down, side to side, a bottom side
optional;

All-metal structure, seismic, pressure, temperature, corrosion resistance;

Variety of connections: flanged, threaded, fast card and other equipment;

Range ratio: 10: 1 special can be 20: 1;

Variety of power supply (220V AC, 24V DC, battery-powered);

Material specifications: 304, 316, 316L, Hastelloy, PTFE lined, etc

Standard output (current 4 ~ 20mA, available with HART communication);
2.4 product function
LCD: You can customize the display of instantaneous value, the accumulated value,
current output value, percent of range;
Output signal: 4 ~ 20mA two-wire output;
HART Communication: Supports universal HART protocol;
Configuration features: engineering units, state media, medium density, operating
Protection function: to set upper and lower limit guard values; below the lower limit
or above the upper limit output 3.8mA or 22mA.
Monitoring functions: on-line monitoring of instantaneous value, the percentage of the
output current, the accumulated value of the like;
pressure, operating temperature, the density of the float,
measuring range, display variables, alarm and other protection
configuration; and having cleared the cumulative flow, zero
correction;
4
;

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ht50Ht51Ht52Ht53Ht54Ht55 ... Show all

Table of Contents