HollySys HT5 Series Instructions For Use Manual page 10

Metal tube flowmeter
Table of Contents

Advertisement

HT5 series metal tube flowmeter
Product
Model
Technical
Parameters
Meter diameter
Measuring range
Range ratio
Accuracy
Mounting height
Wetted materials
Pressure Level
Connection
Ambient temperature
Medium temperature
Signal output
Power supply
Explosion levels
Protection class
Medium viscosity
Display method
Electricalconnections
HT54
DN15~DN100
water(20°)16~100000L/h
air(20°0.1013MPa)
0.5~3000m3/h
Standard :10:1; Particular :20:1
Standard :250mm( Particular, please consult the manufacturer )
R0:316;R1:304;RL:316L;
Standard :DN15~DN50 4.0MPa
Particular, please consult the
manufacturer
Pipe thread ; Threaded SMS
-40℃~120℃, Flameproof :-20℃~+40℃,Intrinsically Safe :-20℃~+40℃
Standard -40℃~+120℃; Particular -80℃~+350℃
Two-wire4 ~ 20mA output;Hart communication;Two-wire sensor threshold
Standard :24VDC(10.8VDC~28VDC) AC type :220VAC(85~265VAC)
Battery type :3.6V-9Ah lithium battery
Intrinsically Safe :Exia II CT6 Ga
water(20°)16~100000L/h
1.0;1.5
R0(316); R1(304) ; RL(316L) ;
Standard :DN15~DN100 1.6MPa
Particular, please consult the
Jacket (quick connector)
switch ,8VDC power supply;
Flameproof :Exd II CT6 Gb
IP65
DN15: ≤5mpa.s(H15.1~15.3)
≤30mpa.s(H15.4~15.9)
DN25: ≤250mpa.s
DN50~DN100:≤300mpa.s
Scene pointer display; LCD
1/2"NPT;M20×1.5;
7
HT55
DN15~DN100
air(20°0.1013MPa)
0.5~3000m3/h
manufacturer