Goodwe SBP Series User Manual
Hide thumbs Also See for SBP Series:

Advertisement

PV Master App
SEMS Portal App
SEMS Portal website
LinkedIn
Company's
www.semsportal.com
offical website
SBP SERIES USER MANUAL
JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD
No. 90 Zijin Rd., New District, Suzhou, 215011, China
AC-COUPLED BATTERY STORAGE RETROFIT
www.goodwe.com
340-00087-05
Ver. 1.5
service@goodwe.com

Advertisement

Table of Contents
loading

Summary of Contents for Goodwe SBP Series

  • Page 1 PV Master App SEMS Portal App SEMS Portal website LinkedIn Company's www.semsportal.com offical website SBP SERIES USER MANUAL JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD No. 90 Zijin Rd., New District, Suzhou, 215011, China AC-COUPLED BATTERY STORAGE RETROFIT www.goodwe.com 340-00087-05 Ver. 1.5 service@goodwe.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION 1.1 Operation Modes Introduction 1.2 Safety & Warning 1.3 Product Overview INSTALLATION INSTRUCTIONS 2.1 Unacceptable Installations 2.2 Packing List 2.3 Mounting 2.3.1 Select Mounting Location 2.3.2 Mounting 2.4 Electrical Wiring Connection 2.4.1 Battery Wiring Connection 2.4.2 On-Grid & Back-Up Connection 2.4.3 Smart Meter &...
  • Page 3: Introduction

    The S-BP series inverter of Jiangsu GoodWe Power Supply Technology Co., Ltd. (hereinafter GoodWe S-BP series bi-directional inverter is designed for both indoor and outdoor use, which called as GoodWe) strictly complies with related safety rules for product design and testing.
  • Page 4: Product Overview

    1.3 Product Overview Safety warning Any installation and operation on inverter must be performed by qualified electricians, in compli- ance with standards, wiring rules or requirements of local grid authorities or companies (like AS 4777 and AS/NZS 3000 in Australia). Prohibit inserting and pulling the AC and DC terminals when the inverter is running.
  • Page 5: Installation Instructions

    PART 3 equipment.[1] QUICK BATTERY Wi-Fi INSTALLATION CONNECTION CONFIGURATION SBP SERIES USER MANUAL JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD No. 90 Zijin Rd., New District, Suzhou, 215011, China www.goodwe.com AC-COUPLED BATTERY STORAGE RETROFIT service@goodwe.com 340-00087-04 Battery Terminal PE Terminal Expansion Bolts...
  • Page 6: Mounting

    2.3.2 Mounting Step 2 Deliver the inverter carefully. Carry the inverter by holding the heating sink on both sides and place the inverter on the mounting bracket. • Pack the inverter securely for transport. • Carefully transport the inverter using the carrying handles in the boxes. Note: Make sure the heat sink on the inverter joints with mounting bracket.
  • Page 7: Electrical Wiring Connection

    • For lithium battery (pack) the capacity should be 50Ah or larger. lead acid batteries are not • Battery voltage lower than discharge voltage allowed for use with GoodWe hybrid inverters without GoodWe's authority. Battery cable • Battery over temperature protection requirement are shown below.
  • Page 8 Conductor wire length 7-9 mm GoodWe shall not cover the standard warranty and be liable for any consequences arising from Conductor core section 4-6 mm users not following this instruction.
  • Page 9: Smart Meter & Ct Connection

    Inverter will restart itself if overload protection occurs. The preparation time for restarting will 1. Please use the Smart Meter with 3 CTs in GoodWe product box. extend (max one hour) if overload protection repeats. Take following steps to restart inverter 2.
  • Page 10: Earth Fault Alarm Connection

    European countries), in compliance with Australia and New Zealand safety requirements( or the No. 5 and 6 holes respectively.) European countries). And DRED device is not provided by GoodWe. The function of each connection position as below: Detailed connection of DRED device is shown below:...
  • Page 11 Wiring System For S-BP Series hybrid inverter SYSTEM CONNECTION DIAGRAMS For 3-phase Smart Meter wiring connection, please refer to "3-phase Smart Meter & CT Note: For Australia safety country, the neutral cable of on-grid side and back-up side must be connected Connection Diagram"...
  • Page 12: Manual Operation

    MAMUAL OPERATION Step 3 1. Fill in the password of ther router, then click 3.1 Wi-Fi Configuration Add wireless network manually "Next". Network name (SSID) WiFi-Test This part shows configuration on the web page. Encryption method WPA/WPA2-PSK Wi-Fi configuration is absolutely necessary for online monitoring and maintenance. Encryption algorithm Please enter the wireless network passwork: Preparation:...
  • Page 13: Pv Master App

    Operation Model Normal Meter Communication Status CT connection BMS Communication Status Alarm warning Please download "PV Master App" from www.goodwe.com or scan Back-Up Switch the QR code on the back of this user manual. Anti-Reverse Function Switch Off Overview Param 3.3 CEI Auto-Test Function...
  • Page 14: Others

    DC Injection High Inverter detects a higher DC component in AC output Try to restart inverter, check if it still occurs, if not, means it is just an occasional situation or contact GoodWe. EEPROM R/W Failure Caused by a strong external magnetic field etc.
  • Page 15: Troubleshootings

    4.2 Troubleshootings Possible problems during operation Checking Before Starting S-BP Up S-BP does not start up with only battery Solution: Battery connection: Make sure the voltage of battery is higher than 48V, otherwise battery cannot start S-BP up. Confirm the conncetion between S-BP and battery : polarity (+/-) are not reversed, refer to 4.2-1. On-Grid &...
  • Page 16 3. An electrical short circuit occurred on battery connection side. Or other reasons please A: Please refer to user manual on page 11. contact GoodWe for details. Q: Will the warranty of the inverter still be valid if for some special conditions we cannot...
  • Page 17: Disclaimer

    4.3 Disclaimer 4.4 Technical Parameters The S-BP series inverters are transported, used and operated under environmental and electrical Technical Data GW3600S-BP GW5000S-BP conditions. Manufacturer has the right not to provide after-sales services or assistance under Battery Input Data following conditions: Li-Ion Battery Type Nominal Battery Voltage (V)
  • Page 18: Other Test

    4.5 Other Test General Data Operating Temperature Range (℃) -25~60 For Australian requirements, in the THDi test, Zref should be added between inverter and mains. Relative Humidity 0~95% RA, XA for Line conduvtor Operating Altitude (m) 4000 Cooling Nature Convection RN, XN for Neutral conductor Noise (dB) <25...
  • Page 19 Moisture location category definition Level Moisture Parameters 4K4H Temperature Range 0~+40℃ -33~+40℃ ~20~+55℃ Moisture Parameters 5%~85% 15%~100% 4%~100% Environment category definition Environment Condition Ambient Termperature Relative Humidity Applied to Outdoor -20~50℃ 4%~100% Indoor Unconditioned -20~50℃ 5%~95% Indoor conditioned 0~40℃ 5%~85% Pollution degree definition No pollution or only dry, non-conductive polllution occurs.

This manual is also suitable for:

Gw3600s-bpGw5000s-bp

Table of Contents