Contact Closure Control; Rs232 Control; Rs232 Commands - Kindermann 5778 000 150 Mounting And Operating Instructions

Hdmi switch 41 4k60 kvm
Hide thumbs Also See for 5778 000 150:
Table of Contents

Advertisement

Available languages

Available languages

7. Contact closure control

The contact closure control can be used for input source selection and to switch the screen to black
temporarely. The inputs are marked with GR1 to GR4 and related to the HDMI imput with the
correspondant number.
PIN assignment:
• BO switches screen to black
• SM switches the input
is the common ground
is the common ground

8. RS232 control

Connect the RS232 port to control HDMI Switch 41 4K60 KVM e. g. from a media control system using
a suitable RS232 cable.
The below command lists are used to control the switcher.
RS232 Communication protocol:
• Baud rate: 9600 (default)
• Data bit: 8
• Stop bit: 1
• Parity bit: none

8.1. RS232 commands

Note:
• All commands need to be ended with "<CR><LF>"
• Please type the command carefully due to case-sensitive
• Using a PC based software like Hterm or Docklight could be helpful for the initial setup
and troubleshooting