8.1.6. Baud rate settings

Command
#SET_RS232_BAUD 1
#SET_RS232_BAUD 2
#SET_RS232_BAUD 3
#SET_RS232_BAUD 4
#SET_RS232_BAUD 5
#GET_RS232_BAUD

8.1.7. Video output control

Command
#SET_THE_DISPLAY_TO 0
#SET_THE_DISPLAY_TO 1
#GET_THE_DISPLAY

9. Firmware upgrade

Please follow the steps below to upgrade firmware by the FW port on the front panel:
1.
Prepare the latest upgrade file (.bin) and rename it to "FW_MERG.bin".
2. Power off the switcher, and connect the FW port to the PC using a suitable USB cable.
3. Power on the switcher, the PC will automatically detect a U-disk named of "BOOTDISK".
4. Open the U-disk, "READY.TXT" should be available.
5. Directly copy the upgrade file ("FW_MERG.bin") to the root folder.
6. Refresh U-disk to check whether the filename "READY.TXT" has been replaced by "SUCCESS.TXT".
If yes, the upgrade was successfully, otherwise it failed. Please check the file and file name of .bin file
and repeat the procedure.
7.
Remove the USB cable.
8. Factory default should be restored by sending the RS232 command and reboot the device afterwards.
Description
Set RS232 baud rate to 9600 (default)
Set RS232 baud rate to 19200
Set RS232 baud rate to 38400
Set RS232 baud rate to 57600
Set RS232 baud rate to 115200
Get the RS232 baud rate
Description
Set output to display black screen
Set output to display live output
Get the status of display device
Command feedback
@RS232 BAUDRATE IS 1!
@RS232 BAUDRATE IS 2!
@RS232 BAUDRATE IS 3!
@RS232 BAUDRATE IS 4!
@RS232 BAUDRATE IS 5!
@RS232 BAUDRATE IS 1!
Command feedback
@THE DISPLAY SIDE SCREEN IS
BLACK!
@THE DISPLAY IS ALREADY OFF!
@WAKE UP THE SCREEN!
@THE DISPLAY IS ALREADY ON!
@THE DISPLAY IS OFF!
@THE DISPLAY IS ON!