Mod.
1060
DS 1060-112B
LBT 20367
POSTO ESTERNO VIDEO IP CON 2 TASTI
EXTERNAL IP VIDEO STATION WITH 2 PUSH BUTTONS
POSTE EXTERNE VIDÉO IP AVEC 2 TOUCHES
MICROALTAVOZ VIDÉO SOBRE IP CON 2 TECLAS
IP-VIDEOAUSSENSTELLE MIT 2 TASTEN
Sch./Ref. 1060/74 (50 Hz)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sinthesi Steel 1060/74 and is the answer not in the manual?

Questions and answers

Summary of Contents for urmet domus Sinthesi Steel 1060/74

  • Page 1 Mod. 1060 DS 1060-112B LBT 20367 POSTO ESTERNO VIDEO IP CON 2 TASTI EXTERNAL IP VIDEO STATION WITH 2 PUSH BUTTONS POSTE EXTERNE VIDÉO IP AVEC 2 TOUCHES MICROALTAVOZ VIDÉO SOBRE IP CON 2 TECLAS IP-VIDEOAUSSENSTELLE MIT 2 TASTEN Sch./Ref. 1060/74 (50 Hz)
  • Page 2 ENGLISH PERFORMANCE The features of the IP video door phone on are the following: • Designed on 2-module Sinthesi Steel style. • Management of pedestrian door electric lock with pulse capacitive discharge and with low holding current (SE+; SE-). • Management of driveway electric lock with relay SE2 with clean contacts (C-NC-NO).
  • Page 3 DIGITAL CONNECTOR Connector for module connector for with voice messages button modules and led Ref. 1158/47 with expansion Ref. 1158/82 - /84 Ref.1158/42 Ref.1145/52 Ref.1158/43 Ref.1145/53 Ref.1158/44 Ref.1145/54 Dummy transparent name holder. Final engraved name holder. DS1060-112B...
  • Page 4 DESCRIPTION OF TERMINALS Terminal pins of discharge electric lock with holding current for relay, if present Common lock relay contact Normally closed lock relay contact Normally open lock relay contact Auxiliary power terminals Terminal pins for external lighting of name holder tags Hall button terminals for operating lock relay Door open sensor terminals Reference for external camera signal...
  • Page 5 EXTERNAL CAMERA CONNECTION Instead of the camera present in the module, an external camera can be connected to terminal pins V3, V5. To enable the external camera, move the jumper as shown below. TLC-EXT WIRING INSTRUCTIONS WITH CAT5 WIRE Fit the CAT5 wire in a RJ45 plug with Urmet logo: •...
  • Page 6 DS 1060-112B LBT 20367 URMET S.p.A. Area tecnica 10154 TORINO (ITALY) servizio clienti +39 011.23.39.810 VIA BOLOGNA 188/C http://www.urmet.com Telef. +39 011.24.00.000 (RIC. AUT.) e-mail: info@urmet.com +39 011.24.00.300 - 323 MADE IN ITALY...