DIMENSIONS
Please keep this instruction manual for future reference
20
Instruction manual C749G
Dimension:
Width -
590mm
Depth -
510mm
Height - 90mm
Gas connection:
G1/2 thread
Electric supply:
110~240V ac,50Hz/60Hz, 2W
Cooking output:
4 Gas Burners
Rapid burner : 3kW
Semi-rapid burner: 1.75kW
Simmer burner : 1kW
TROUBLE SHOOTING
Problem
Probable cause
No Spark.
Not ignited.
The burner lid is badly assembled. Assemble the lid correctly.
The gas supply is closed.
The gas supply is not completely
open.
The burner lid is badly assembled. Assemble the lid correctly.
The ignition plug is contaminated
Badly ignited.
with alien substance.
The burners are wet.
The holes in the flame spreader
are clogged.
Noise made when
combusted and
The burner lid is badly assembled. Assemble the burner lid correctly.
ignited.
The flame supervision device
is contaminated with an alien
substance.
Flame goes out
Product being cooked has boiled
when in use.
over and extinguished the flame.
A strong draught may have blown
the flame out.
The holes in the flame spreader
are clogged.
Yellow Flame.
Different gas is used.
Unstable Flame.
The burner lid is badly assembled. Assemble the burner lid correctly.
Gas Smell.
Gas leakage.
Solution
Check the electricity supply.
Open the gas supply completely.
Open the gas supply completely.
Wipe alien substance with a dry cloth.
Dry the burners lids carefully.
Clean the flame spreader.
Clean the flame supervision device.
Turn off burner knob. Wait one minute
and reignite zone.
Please turn off zone and check cooking
area for draught such as open windows.
Wait 1 minute and reignite zone.
Clean the flame spreader.
Check the gas used.
Stop using the product and close the
main supply valve. Open the window to
ventilate. Contact Caple Service and your
gas supplier.
Please keep this instruction manual for future reference
Instruction manual C749G
21
Need help?
Do you have a question about the C749G and is the answer not in the manual?