Start-Up Time; Hold-Up Time; Dynamic Response - Delta PJB-24V100WA Technical Data Sheet

Open frame power supply
Table of Contents

Advertisement

TECHNICAL DATASHEET
PJB Open Frame Power Supply
24V 100W 1 Phase / PJB-24V100W
Functions

Start-up Time

The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its final steady state set value.

Hold-up Time

Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time

Dynamic Response

The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load 0% to 100% of its
rated current.
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
11
www.DeltaPSU.com (October 2020, Rev. 03)
A
□□