TECHNICAL DATA
Model
Output
(1)
Delivery
(1)
Fuel
Operation
Nozzle
Standard applications
Ambient temperature
Combustion air temperature
Main power supply (+/- 10%)
Fan motor
Ignition transformer
Pump TA3
delivery (at 290 PSI)
pressure range
fuel temperature
Electrical power consumption
Electrical protection
Noise levels
(2)
Reference conditions: Ambient temperature 68 °F (20 °C) - Barometric pressure 394" WC - Altitude 329 ft a.s.l.
(1)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(2)
Equivalent Btu values based on 1 USGPH = 140,000 Btu/hr.
(3)
Burner models designations:
Model
C9517300 (3477870)
C9517301 (3477875)
RL 190/M
C9717300 (3477873)
C9717301 (3477873)
ACCESSORIES
(optional):
• Available auxiliary panels
Auxiliary panel code
3010330
3010334
•
Flame inversion boiler kit cod. 3010241
Important:
The installer is responsible for the supply and installation of any safety device(s) not indicated in this manual.
High
MBtu/hr
GPH
Low
MBtu/hr
GPH
number
°F
°F max
V/Ph/Hz
rpm
W - HP
V1 - V2
I1 - I2
GPH
PSI
°F max
W max
dBA
Code
Voltage
208-230/460/3/60
575/3/60
208-230/460/3/60
575/3/60
Flame safeguard type
Fireye
Landis
(3)
(3)
Boilers: water, steam, thermal oil
208 - 230 / 460 / 575 / 3 / 60
V
A
Flame safeguard
Burner mounted
Burner mounted
In an auxiliary panel (see Accessories)
In an auxiliary panel (see Accessories)
3
RL 190/M
5376 - 9184
38.4 - 65.6
1792 - 5376
12.8 - 38.4
#2 fuel oil
Low - high or modulating
1 (return flow nozzle)
32 - 104 (0 - 40 °C)
140 (60 °C)
3400
4000 - 5.5
208 - 230 / 460 / 575
15.8 - 9.1 - 6
120 V - 2 x 5 kV
3.7 A - 35 mA
213
101.5 - 580
284
5500
NEMA1
83.9