ELECTRICAL CONNECTIONS AND WIRING
Three phase electrical
characteristics
(Locked Rotor Amp)
Compressor
model
3
NTZ048
32
NTZ068
48.5
NTZ096
72
NTZ108
72
NTZ136
97.2
NTZ215
147.7
NTZ271
198
Three phase motor
protection and
suggested wiring
diagram
FU
Fuses
MS
Main switch
C1
Compressor contactor
TH
Thermostat
EC
External controls
COMP
Compressor
PTC
Crankcase heater
IOL
Internal overload line break
LRA
(Maximum Continuous Current)
A
4
9
16
22
10.1
25
29
14.8
32
20.4
45
57
21.4
51
64
29
74
110
42.3
96
150
56.5
Three phase compressors are inter-
nally protected by a temperature /
current-sensing bimetallic protector,
connected to the neutral point of the
star-connected stator windings. This
internal overload line break protects
the motor against overheating, cur-
MCC
A
3
4
9
4.8
5
8.4
8.5
10.1
12.1
11
14.3
15
22.3
23
27.0
30
FU
MS
C1
Comp.
IOL
Winding resistance
(between phases +/- 7% at 25°C)
Ohm
3
4
2.80
11.55
1.58
7.11
1.20
5.03
1.20
4.00
0.98
3.80
0.57
2.23
0.41
1.61
rent overload and locked rotor con-
ditions. If the motor were to be over-
loaded and the protector trips, all
3-phases are cut out. It might take up
to several hours to reset and restart
the compressor.
FU
TH
EC
PTC
C1
9
13.10
9.70
2.54
2.54
1.26
0.84
L1
L2
L3
N
13