2-way servo proportional valves with vcd-technology

Advertisement

Quick Links

Bulletin MSG11-5715-697/UK
Operation Manual
Series TDP/TEP
Design ≥ 60
2-Way Servo
Proportional Valves with
®
VCD
-Technology
Parker Hannifin
Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.: (+49) 181 99 44 43 0
E-mail: valvesisde@parker.com
Copyright © 2020, Parker Hannifin Corp.

Advertisement

Table of Contents
loading

Summary of Contents for Parker TDP Series

  • Page 1 Design ≥ 60 2-Way Servo Proportional Valves with ® -Technology Parker Hannifin Manufacturing Germany GmbH & Co. KG Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com Copyright © 2020, Parker Hannifin Corp.
  • Page 2 The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
  • Page 3: Table Of Contents

    Pressure Fluids Electrical Connection Electrical Interfacing 5. Operation Instructions Solenoid Current Monitoring ProPxD Parameterizing Software Shut-off Valve TEP Air Bleeding of Hydraulic System Filter Flushing 6. Troubleshooting 7. Accessories / Spare Parts Accessories Spare Parts TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 4: Introduction

    Operation Manual Series TDP/TEP 1. Introduction ® Parker 2-way servo proportional valves with VCD technology have an integrated electronics and re- quire only one sole electrical common for the control system. Different flow sizes are available to achieve an optimal adaption for different applications.
  • Page 5: Order Code Tdp

    Code Seal Please order connector separately. for HFC fluid Angle female connector must be used for NG25 to NG50. For HFC fluids suitable Please order female connector M12 x 1 separately (order no.: 5004109). TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 6: Technical Data

    If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability. TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 7: Block Diagram Of Integral Electronics

    6 + PE acc. EN 175201-804 Wiring min. [mm²] 7 x 1.0 (AWG16) overall braid shield Wiring lenght max. [m] 50 Block Diagram of Integrated Electronics Do not connect with the supply voltage zero. TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 8: Safety Instructions

    Service Do not disassemble the valve! In case of Workings in the area of installation, commissioning, suspicion for a defect please contact Parker. maintenance and repair of the valve may only be Storage allowed by qualified personnel. This means persons...
  • Page 9: Mounting / Installation

    HFC: choose the right seal option for series TEP. Special gaskets may be available depending on Choose seal option code N for series TDP. the utilized fluid. In case of doubt please consult Parker. TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 10: Electrical Connection

    8...12 mm Cable length max. 50 m Female connector (ordering no. 5004072) For NG63 up to NG100 For cable lengths > 50 m consult Parker. 7/8-20 max. 67 UNEF-2B The connection cable is coupled to the female connector by solder joints.
  • Page 11: Electrical Interfacing

    (cross section AWG 6). Wiring Diagram of Supply Voltage control system valve 22...30 V 4 Am TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 12 4…12 mA 0…-10 V 4…12 mA 0…+10 V 12…20 mA 0…+10 V 12…20 mA 0…-10 V Cable break, Cable break, 0…3.6 mA 0…3.6 mA 12.5 V 12.5 V Overload 12.5 V Overload 12.5 V TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 13: Operation Instructions

    The PC software can be downloaded free of charge Plug for at www.parker.com/isde - see page “Support” or parametering interface directly at www.parker.com/propxd. For program installation and software operating please see operation manual 5715-687.
  • Page 14 Closer information can be can be displayed via the ProPxD Parametrier software. Error code Error code Error description (additive) no errors over current cable break command signal cable break feedback signal undervoltage error bus communication error hardware failure TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 15: Shut-Off Valve Tep

    2006/42/EC. Length Max. 50 m Electronic Control System For lengths >50 m please contact Parker. The D3DW valve must be operated by the user The sealing surface of the valve must be with a suitable control system. properly connected to the earthed frame of The valve is connected using separate wires for the machine.
  • Page 16 Leaking only way to ensure that position control works plugs may constitute a safety hazard, so the properly valve must be returned to the manufacturer TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 17 To guarantee that the main piston operates reliably at all times, the minimum pilot pressure must be provided. To achieve this, a suitable combination of flow and return arrangements must be selected for the pilot oil. TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 18 Operation Manual Series TDP/TEP Declaration of Conformity unacceptable degree. This would invalidate Any unauthorised structural change or addi- the declaration of conformity supplied with tion to the product may jeopardise safety to an the product. TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 19 • Voltage spikes occurring when inductive loads • Connections must follow the connection list. are removed should be eliminated using a suitable protection circuit, for example flyback diodes. Connection Diagram Only guaranted with screened cable and female connector TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 20 When the trip point is reached, pin 4 is non conducting, this means a normally closed function. Simultaneously pin 2 becomes conduct- ing, this means a normally open function. Wirings Installation Please order plug M12x1 separately. Order no.: 5004109 TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 21: Air Bleeding Of Hydraulic System

    X X contacts of central connector contaminated clean contacts / replace plug feed cable interrupted fix feed cable X X X X X X wiring sequence incorrect correct wiring sequence X feed cable without shielding change cable grade TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...
  • Page 22: Accessories / Spare Parts

    Please direct technical product enquiries to: Parker Hannifin Manufacturing Germany GmbH & Co. KG Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com Hotline in Europe Tel.: 00800-2727-5374 TDP_TEP 5715-697UK.indd 05.11.20 Parker Hannifin Corporation...