The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
Scope of Supply Mounting Available Bolts Kits Limits of Use Pressure Fluids Electrical Connection Electrical Interfacing Operation Instructions ProPxD Parameterizing Software Air Bleeding of Hydraulic System Filter Flushing Troubleshooting Accessories / Spare Parts Accessories Spare Parts TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
Operation Manual Series TDC 1. Introduction TDC040 Parker TDC 2-way high performance proportional throttle valves have an integral electronics and require only one single electrical common cable for the control system. Different flow sizes are available to achieve an optimal adaption for different applications.
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability. TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
• operation outside the specifications tives and approved technical rules. Do not disassemble the valve! In case of suspicion for a defect please contact Parker. Storage In case of temporary storage the valve must be protected against contamination, atmospheric ex- posure and mechanical damages.
VDMA-document 24317 as well as Mineral oil: usable without restriction. DIN 51524 & 51502. Special gaskets may be available depending on the utilized fluid. In case of doubt please consult Parker. TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
It is necessary to Cable length max. 50 m use a low ohmic potential connection between control unit and machine frame to prevent For cable lengths > 50 m consult Parker. earth loops (cross section AWG 6). TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
Preferable the enable signal should valves. be switched on together with the hydraulic pressure supply. This forces the actuator drive into drop out TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
Page 11
0…-20 mA 0…-10 V modulations. Due to the sensitivity of the valve a high signal quality is recommended, this will prevent malfunction. Incorrect signal amplitude levels may disturb the functionality and can damage the valve. TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
Parametrizing cable See www.parker.com/isde section “Support” or Ordering code: 40982923 directly at www.parker.com/propxd for free software download. Parametrizing connection PC side connection valve side connection...
Page 13
ProPxD icon for starting the program. The expert mode is protected by a pass word Software operating request. The name is “parker”. The button “Send Brief instruction for first startup: parameter” appears in the “Expert”-operating mode. This button transmits only the setting of one single •...
Page 14
0 - 32500 ramp decel. AB B To avoid switching noise. Adjustment of the handling by detecting a fault. 0, 255, 768, – Errorhandling For the alignment of the valve reaction at fault diagnosis 1023 TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...
X X contacts of central connector contaminated clean contacts / replace plug feed cable interrupted fix feed cable X X X X X X wiring sequence incorrect correct wiring sequence X feed cable without shielding change cable grade TDC 5715-713UK.indd 29.04.19 Parker Hannifin Corporation...