STATUS message
(G00) COMPLETE
(G10) FLS ERASE
(G11) FLS LOAD xxx%
(G12) FLS VERIFY
(G13) USER ERASE
(G14) USER LOAD xxx%
(G15) USER VERIFY
(G21) FLS TIMEOUT ERROR
(G22) FLS FILE OPEN ERROR
(G23) FLS FILE FORMAT ERROR
(G24) FLS FILE SIZE OVER
(G25) FLS FILE ADDRESS OVER
(G26) FLS LOAD VERIFY ERROR
(G27) FLS UNEXPECTED ERROR
(G31) USER TIMEOUT ERROR
(G32) USER FILE OPEN ERROR
(G33) USER FILE FORMAT ERROR
(G34) USER FILE SIZE OVER
(G35) USER FILE ADDRESS OVER
(G36) USER LOAD VERIFY ERROR
(G37) USER UNEXPECTED ERROR
(G99) ICD COMMUNICATION ERROR
Display message number classification
(G00): Loading has completed successfully.
(G1x): Data is being loading.
(G2x): An error has occurred during loading FLS.
(G3x): An error has occurred during loading the user program data.
(G99): Communication with the ICDmini has not been established.
S5U1C17001Y23 Multi-Programmer
System Manual (Rev. 1.1)
Table 6.4.2 List of STATUS Massages
Loading FLS and the user program data to the ICDmini has completed
successfully.
FLS storage area is being erased.
FLS is being loaded (0% to 100%).
FLS storage area is being verified.
User program data storage area is being erased.
User program data is being loaded (0% to 100%)
User program data storage area is being verified.
A communication time-out has occurred during loading FLS to the ICDmini.
The FLS file cannot be opened.
The FLS file format is invalid. (It is not a Motorola format.)
The FLS file size exceeds 8KB.
The address in the FLS file exceeds the 24-bit range.
An error has occurred during verify check after loading FLS to the ICDmini.
Unexpected error has occurred during loading FLS to the ICDmini.
A communication time-out has occurred during loading the user program
data to the ICDmini.
The user program data file cannot be opened.
The user program data file format is invalid. (It is not a Motorola format.)
The user program data file size exceeds 4MB.
The address in the user program data file exceeds the 24-bit range.
An error has occurred during verify check after loading the user program
data to the ICDmini.
Unexpected error has occurred during loading the user program data to the
ICDmini.
Communication with the ICDmini cannot be established.