ACCUMULATORS

To view the accumulators:

1. Press the ACCUM key. The display will show ACC= and flash the ACCUM annunciator.
2. Press the ID, PRESET, GROSS, or NET keys to select the type of accumulator to view.
To view a single ID accumulator, press the ID key. The display will show id=. Input the ID
number to be viewed (1 - 999,999) and press the ENTER key. The accumulator value of the ID
entered will be displayed or if the accumulator value is greater than (>) 999,999, -0F- will be
displayed..
To view a single Preset accumulator, press the PRESET key. The display will show bin=.
Input the bin number (1 - 8) and press the ENTER key. The accumulator value of the Preset
entered wll be displayed or if the accumulator value is greater than (>) 999,999, -0F- will be
displayed.
To view the Gross or Net accumulators, press the appropriate key. The accumulator value will
be displayed without any additional prompts or if the accumulator value is greater than (>)
999,999, -0F- will be displayed..
3. Pres the ENTER key to return to normal operation.

To print a single ID accumulator

1. Press the ACCUM key. The display will show ACC= and flash the ACCUM annunciator.
2. Press the ID key.
3. Input the ID number (1 - 999,999) and press the ENTER key.
4. Press the PRINT key.
5. The accumulator value for the ID entered will be printed.
6. The indicator will return to normal operation when printing has been completed.

To print all active ID accumulators:

1. Press the ACCUM key. The display will show ACC= and flash the ACCUM annunciator.
2. Press the ID key. The indicator will display ALL= and flash the ID annunciator.
3. Press the PRINT key.
4. The accumulator values for ALL active ID's will be printed.
5. The indicator will return to normal operation when printing has been completed.
To zero a single ID accumulator:
1. Press the ACCUM key. The display will show ACC= and flash the ACCUM annunciator.
2. Press the ID key. The indicator will display ALL= and flash the ID annunciator.
3. Press the 0 key (0 = NO). The display will show id=.
4. Input the ID number (1 - 999,999) and press the ENTER key.
5. Press the ZERO key.
6. The accumulator values for ALL active ID's will be printed.
7. The indicator will return to normal operation when printing has been completed.
To zero all active ID accumulators:
1. Press the ACCUM key. The display will show ACC= and flash the ACCUM annunciator.
2. Press the ID key. The indicator will display ALL= and flash the ID annunciator.
3. Press the ZERO key.
4. The accumulator values for ALL active ID's will be printed.
5. The indicator will return to normal operation when printing has been completed.
To print a single Preset accumulator:
1. Press the ACCUM key. The display will show ACC= and flash the ACCUM annunciator.
2. Press the PRESET key. The indicator will display ALL= and flash the BIN/PWC annunciator.
3. Press the 0 key (0 = NO). The display will show bin=.
4. Input the bin (preset) number (1 - 8) and press the ENTER key.
5. Press the PRINT key.
6. The accumulator values for the preset (bin) entered will be printed.
7. The indicator will return to normal operation when printing has been completed.