9629 Microprocessor Controller
C.

Interconnections

The 9629 control can be connected to other
devices to as part of a complete welding sys-
tem. Standard length cables, complete with the
appropriate Amphenol connectors are available
from Jetline. Special length cables can be made
to order.
The example illustrated below shows the sim-
plest application. In this case the 9629 control
is connected to the wire feed drive unit as a
stand-alone product.
The control is shown also connected to a Miller
Maxstar DX power supply. This is necessary if
the 9629 control is fitted with the pulse option
and it is desired to synchronize the pulsing of the
wire with the pulsing of the weld current.
9629 CONTROL, WIRE FEEDER AND POWER SUPPLY
Note: The Miller range of TIG welding power
supplies are available with a special 10-pin
connector, this permits easy communication
between the 9629 and the power supply. Power
supplies from other manufacturers can be used,
if so, consult Jetline for details of interconnec-
tion cables and required interfaces.
Required Connections and Cables:
S1:
Unused
S2:
9629 to welding power supply.
Cable: 9600S2-DX10-15 (For Miller)
S3:
9629 to wire drive motor
Cable: Included with wire feed head
9629