Calibration Mode - Jetline 9600 Series Operation Manual

Microprocessor controller
Table of Contents

Advertisement

9629 Microprocessor Controller
decrease its value. As the change is made, the
number on the display changes accordingly.
The high pulse time can be set from 0.05 to 5.00
seconds.
Press the touch pad with the down arrow to
proceed to the next screen.
Screen 16 LOW PULSE
LOW PULSE
This screen allows the time during which the
wire feeds at the programmed low wire feed
speed to be set. The time is set (in 0.05 sec-
ond increments) by turning the adjust knob to
increase or decrease its value. As the change
is made, the number on the display changes
accordingly.
The low pulse time can be set from 0.05 to 5.00
seconds.
There are no further screens in the set-up mode
of operation of the 9629 control.
C.

Calibration Mode

This mode is used to configure and calibrate the
unit. To enter the calibration mode, the follow-
ing procedure must be followed:
• Press and hold both reverse and forward jog
touch pads.
• While pressing the touch pads, press and re-
lease the power on push-button switch.
• Continue to press the reverse and forward jog
touch pads until the first welcome screen has
changed to the first calibration screen (approxi-
mately 3 seconds).
• Remove the pressure from the touch pads.
This now sets the 9629 control into the calibra-
tion mode.
0.50sec
Calibration Screens
Screen 17 CLOSED LOOP MODE
This screen allows the closed loop mode to be
turned On or Off, this is achieved by turning
the adjust knob.
When the closed loop mode is switched to On,
it is necessary for the control to receive a suit-
able signal from a tach-generator on the wire
feed motor.
Operating the control in closed loop mode results
in increased travel speed accuracy (better than
+1% of the rated speed).
If closed loop mode is set to Off, the next
screen will not appear, the system will proceed
to Screen 20.
Press the touch pad with the down arrow to
proceed to the next screen.
Screen 18 LOOP SENSING
This screen allows the sensitivity of the closed
loop sensing to be set by turning the adjust knob
to increase or decrease the value. As the change
is made, the number on the display changes.
When closed loop control is used, the control
compares the actual speed (as indicated by the
tach-generator) with the preset speed and makes
a correction 20 times per second. The amount
of each correction is the actual error multiplied
by the percentage number entered as the loop
sensing percentage.
It is recommended that a relatively low number
be selected, the unit is pre-programmed with
10% as the default value. Too high a number
will result in a large correction being sent out
- 22 -
CLOSED LOOP MODE On
LOOP SENSING
7%