Loading the default (factory) settings

8.
When necessary, the factory (default settings) may be applied so the DAEnetIP4
parameters will be loaded back.
When DAEnetIP4 is shipped from the factory, the jumper is placed on JP5 pins 2
and 3.
 Turn off the power supply of the device;
 Move the jumper to the Default Position (between pin 1 and 2);
 Turn on the power supply of the device;
 Wait until the status led become ON (approximately 10 sec);
 Remove the jumper from the Default Position;
 Turn off the power supply of the device;
 Move back the jumper to the middle position (between pin 2 and 3);
 The module is configured with default settings.