External Device Settings
For External Device communication settings, use the FUNC key, Up key, Down key, and STR key located in the
keypad of the External Device.
Refer to your External Device manual for details.
1
Turn ON the External Device.
2
Press FUNC key for 3 seconds or longer.
3
Press FUNC key to display [d001].
4
Press and hold Down key to display [C---].
5
Press FUNC key.
6
Press Up key to display the setting function code.
7
Press FUNC key.
8
Press Up key or Down key to select the setting value.
9
Press STR key.
10
Reboot the External Device.
Setting Value
Function Code
C071
C072
C073
C074
C075
C076
C077
C078
C079
A001
A002
GP-Pro EX Device/PLC Connection Manual
Setting Value
06
Communication speed selection
1.
Node allocation
8
Communication data length selection
00
Communication parity selection
1
Communication stop bit selection
02
Selection of operation after communication error
0.00
Communication trip limit time setting
0.
Communication wait time
01
Communication mode selection
03
Frequency source setting
03
Run command source setting
10
Inverter MODBUS RTU Driver
Setup Description