Electrical connection

Wiring diagram for the connection of tubular motors.
Before connection, please read the operating manuals for the relevant
tubular motor.
When connecting RADEMACHER tubular motors
with mechanical end point settings, or the tubular
motors of other manufacturers, a circuit bridge on
the printed circuit board of the DuoFern Environ-
mental Sensor must first be removed, otherwise
damage may occur to the DuoFern Environmental
Sensor and drive.
Use of the setting wire for electronic
RADEMACHER tubular motors:
After connection of an electronic RADEMACHER tubular
motor, the setting wire must be connected to the neutral
conductor (N) without fail.
L1
N
38
ATTENTION!
N S
i
▲ ▼ N
S
M
The earthing must also be
connected when connec-
ting an appliance.
The connecting cable of the tubular
motor may not exceed 3 m.
▲ = Up
▼ = Down
N = Neutral conductor
= Earth
S = Setting wire (if available)
M = Motor
EN