Operating Information-7B92 Service
®
Sweep
Controls
TIME!DIV
OR
DLV TIME
. Selects the basic sweep
rate
for Norm
al
and
AL T
Sweep
operation
and se
lects
the delay
time (to
be
mult
iplied by the DELAV
T
IM
E
MULT
dial
setting)
w
hen
operating
in the INTEN
or
DL
V'D Sweep
mode (see
F
ig.
'
·3)
.
Th
e VAR
IABL
E
control
must be in
the
CAL
position for the
ind
icated
sweep rate.
DL
V'D
Time/Division
. Selects
the
9Neep rate
of
the
delayed
9Neep generator for o peration
in
the
DL
V'D
Sweep, INTEN,
and
AL T
Sweep
Display
Modes
(see
Fig.
'
·3)
.
The
VAR
IAB LE
control
must be in
the
CAL
position for ind
icating the
sweep
rate
.
VARIABLE
. Two·position
9Nitch
actuated
by the
VAR
IAB
LE
control
to
select
calibrated
or uncatibrated
sweep
rates (see Fig.
'
·3).
In the
CAL position
(pressed
in)
t he VAR IAB LE control is inoperative
and
the sweep rate is
calibrated. When pressed
and
released, the knob moves
out
to
activate
the VAR IABLE
control
for
uncalibrated sweep
rates.
The
sweep
rate in
each
Tl
ME/
DIV switch position
can
be reduced
at
least to
the
9Neep
rate of
the next
slower
position. The VA
RI
AB LE
con
trol can be sw itched to
operate
with
either
the
delaying
or
delayed 9Neeps
by
means of
the
internal Variable
Selector multi·pin
con·
nectar.
Display Modes. Four display modes
can be selected
by
the
follOWing
switch
settings:
SWP
VAR IABLE
{
CAL
IN
t
CAl
TIME/DIY
OR
DLY
ALT (OUT
I
o
•
,-OUT
·
DL'I'O SW, TRI
GGfRABU
I
.
,
OIM:
"O"IHI
.
e.
.OlUll'"
NORMAL
Sweep.
A
Normal
Sweep (non·delayed) is
selected
when
the
TI
ME
/
DIV O
R
Dl V
TI
ME switch and
the
Dl V'D T
ime/
Division
switch are locked together
at
the
same sweep rate
(see Fig.
'
·3). The
Dl
V'D
Time!
Division switch
and the Delayed Triggering l
EVE
L
control
must be pressed
in
for the
Normal
Sweep
Mode.
Calibrated sweep
rates
from 0
.2
second/
di vision to 0.5
nanosecond/division
can
be
obtained.
IN TEN. The tNTEN mode
,
a
function
of
the
delayi
ng
and delayed
9Neeps is selected
when
the
DL
V'D
Time/Division
mitch
is pulled
out
and rotated
clockwise
(see Fig.
'
·3). In
th
is
mocle,
a portion
of the delaying
sweep
is
intensified during
the
time that
the delayed
sweep generator runs.
DL V'O
Sweep. The
Dl V'D
Sweep
Display
Mode
is
selected
when
the DL V'D
Time/
Division switch is pulled
out
,
ro
tated
in the INTEN Display Mode for the desired
delayed
sweep
rate,
then
pushed in (see Fig.
'
·3). ln this
Display Mode, the delayed
9Neep
is displayed,
at
a
rate
determined by the
DL V'D
Time/
Division 9Nitch, at the
end of
each
delay period, as selected by the
T
IME/
DIV
OR Dl
V
TI
M E switch
and the
DE LA V
T
IME MUL
T
dial settings.
AL
T Sweep
.
When
the A
L T
switch
is pressed
and
released to the
OUT
position, sweeps from
both
the
delaying
sweep
generator (intensified
sweep) and
de·
layed SNeep generator
(delayed
$\Neep)
are
displayed.
Swilch
$Weep
rite
upon
i
I
NORMAL
Sweep,
INTEN
,
D
ispl
ay Modes .
Fig.
1·3
.
Composi te
Ti
me/
Div
isio
n
swit
ch
.
' ·4
SCOtU
bv
Out.fOurce-Options
:>