Use Case 4: Loop-Through Mode - Barco Njord Installation Manual

Hide thumbs Also See for Njord:
Table of Contents

Advertisement

15.4 Use case 4: Loop-through mode

Loop-through mode
2
3
Image 15–4
1
SFP input board
2
Neutrik OpticalCon Duo
3
Neutrik OpticalCon Quad
Barco delivers only the SFP input and SFP+ fiber transceivers. The customer has to buy the SFP+
transceiver and the optional breakout adapter or the fiber integrated cable.
How to configure the SFP input
1.
Remove both plates covering the access to a Neutrik connector locations.
2.
Mount the Neutrik OpticalCon Quad connector and the Neutrik OpticalCon Duo.
3.
Remove the plate covering the access to the SFP cage and insert the SFP+ transceivers.
4.
Re-install the cover plate.
5.
Mount the fiber internal cables between the Neutrik OpticalCon Quad and the SFP+ transceivers.
6.
Mount the fiber internal cables between the Neutrik OpticalCon Quad and the Neutrik OpticalCon Duo.
7.
Install the SFP input in its slot of the Input & Communication module. See procedure "Installation of an
input board", page 55.
1
6
4
5
Pulse SFP input use cases
4
Internal fiber cable
5
SFP+ fiber transceiver
6
Advanced Quad cable
R5913593 /01
Njord