CHAPTER 2. TECHNICAL SPECIFICATIONS
! !
WARNING
! !
! !
! !
WARNING
CAUTION
! !
! !
! !
NOTICE
CAUTION
WARNING
NOTICE
! !
! !
CAUTION
NOTICE
* VDE agency approval temperature.
†
Air flow over the inverter heat sink, as shown in Figure 3.9.
‡
Ingress Protection grades are described in IEC 60529 (Degrees of protection provided by
enclosures).
• Do not connect the Fullmotion CF10C In-
verter to a power supply above 264 V.
• For operation below the rated voltage, the
maximum compressor cooling capacity
can be reduced as consequence of speed
limitation.
• Confirm compressor type and speed rota-
tion at compressor datasheet.
• In order to avoid loss of performance,
make sure to operate the inverter inside
the temperature range of -20 °C to 50 °C.
• Ambient operation temperature above 50
°C may activate inverter thermal protec-
tion.
• Voltage range relates to product robust-
ness, not institute approval.
• Maximum power is not reached under all
input voltage range.
• Output frequency and motor speed may
have reduced range based on maximum
working conditions of the respective com-
pressor.