Communication Malfunction E6 - Gree LIVV09HP230V1A Series Service & Parts Manual

Hide thumbs Also See for LIVV09HP230V1A Series:
Table of Contents

Advertisement

7. Communication malfunction E6

Cut off power supply. Check if
connection line of IDU and ODU
and the wire inside electric box
are correctly connected.
Correct connection?
Main board matches
with display board? Main board of
IDU matches with that of ODU?
yes
Communication cord is damaged?
Replace IDU's
main board
Malfunction eliminated?
Start
Connect the line
no
according to
wiring diagram.
yes
no
yes
no
no
yes
End
Malfunction eliminated?
no
Match correctly
Malfunction eliminated?
according to product
specification
no
Replace
Malfunction eliminated?
communication
cord
no
Replace ODU's
main board.
68