Removal Procedure Of Indoor Unit; Remove Filter Assembly; Remove Horizontal Louver - Gree LIVV09HP230V1A Series Service & Parts Manual

Hide thumbs Also See for LIVV09HP230V1A Series:
Table of Contents

Advertisement

Service Manual
11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

07/09/12K
Step

1. Remove filter assembly

Open the front panel. Push the left filter
and right filter until they are separate from
the groove on the front panel.
Remove the left filter and right filter
respectively.

2. Remove horizontal louver

Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
3. Remove panel and display
a
C6 panel display: Screw off the 2 screws
that are locking the display board.
Separate the panel rotation shaft from
b
the groove fixing the front panel and then
removes the front panel.
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Procedure
Front panel
Left filter
Horizontal louver
Display
Front panel
Panel rotation
Groove
91
Right filter
Groove
Location of step motor
Axile bush
Panel
C6 display
Front
case

Hide quick links: