Pump On Time; Pump Off Time; Pump Speed 3 - Rheem Raypak 2450 Installation And Operation Manual

Heat pump pool & spa heater
Table of Contents

Advertisement

Item

Pump Off Time 3

Pump Speed 3

Return Valve 3
Suction Valve 3

Pump On Time 4

Pump Off Time 4
Pump Speed 4
Return Valve 4
Suction Valve 4
Faults Last
Clear Faults
Run Hours
XXXX
Cycles
XXXX
26
Default
Range
Value
12:00A–11:59P
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
Pool/Spa
Pool
Pool/Spa
Pool
12:00A–11:59P
12:00A–11:59P
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
Pool/Spa
Pool
Pool/Spa
Pool
(Continued on next page)
Access
Level
Installer
Select OFF time for Pump Period #3 to stop.
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
Installer
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Select the position of a 3-way valve located
Installer
between the heater and the Pool/Spa for this
scheduled pump period.
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
Installer
scheduled pump period.
Select ON time for Pump Period #4 to take
Installer
effect.
Installer
Select OFF time for Pump Period #4 to stop.
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
Installer
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Select the position of a 3-way valve located
Installer
between the heater and the Pool/Spa for this
scheduled pump period.
Select the position of the 3-way valve located
Installer
between the Pool/Spa and the Pump for this
scheduled pump period.
Fault history starting with the most recent
and going back to 10 last faults. Using the
Installer/
UP/DOWN buttons scrolls through the fault
Service
history. If there are no faults present, the
display will read "All Faults Clear".
Holding down the UP and DOWN buttons for
Installer/
3+ seconds clears the recorded fault history
Service
and "Faults Cleared" appears on the display.
Displays the number of run hours that the
Installer/
compressor has been running as well as the
Service
number of cycles that the unit has operated.
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents