Rheem Raypak 2450 Installation And Operation Manual page 40

Heat pump pool & spa heater
Table of Contents

Advertisement

Figure 12. Sheet Metal Screws to remove Junction Box
Panel
6. Remove the 2 screws holding the compressor wire
retainer to the junction box and place them in the
recessed cups in the molded base.
7. Slide the compressor wires out the side of the slot in
the junction box.
8. Lift the junction box slightly (hold onto the bottom
of the junction box like a handle) and pull out at the
bottom to remove the junction box assembly.
WARNING: Care must be taken with the fan and
A
compressor wires when removing junction box.
9. Slide assembly away from the opening to give access
inside the unit. NOTE: The top of the unit may also be
removed for greater access as desired.
10. After service, reposition the junction box and insert
the top first and lift up until the bottom slides into
place against the cabinet and the panel where the
Inlet/Outlet water connections are secured.
A
CAUTION: Ensure that the fan motor wires are
routed into the slot at the top of the junction box. Also
ensure that the compressor wires are routed into the slot
on the right side of the junction box.
40
WARNING: If any wires have come off components
A
during service of this unit, please refer to the wiring
diagram on the back of the control panel cover or in
the I&O manual to ensure that they are returned to the
correct terminals/locations.
11. Reinstall the compressor wire retainer to the
junction box with the 2 screws removed in Step #6.
12. Reinstall the screws removed in Step #5 to secure
the junction box to the cabinet.
13. Reconnect the multi-pin connectors to the control
board.
14. Slide the control box cover into place and secure with
the screws removed in Step #2.
15. Turn ON power and start operation as needed.