HEA T PUMPS
RPNE- SERIES
Seven Models
13 SEER with efficiencies
ranging up to 14 SEER in
certain matched systems.
Nominal Sizes 1
1
/
to 5 Tons
2
[5.28 kW] to [17.58 kW]
13.0
The Rheem Classic
units can provide year-round heating and cooling comfort
for residential, multi-family and light commercial applica-
tions. They are designed to operate with Rheem indoor
units with cooling and heating capacities certified under the
ARI Certification program.
The Rheem RHSA-, RHLA- & RHKA- Air Handlers are
equipped with auxiliary heating elements for supplementary
heat was designed especially for use with the RPNE- Heat
Pump. Together they provide systems capable of delivering
a maximum HSPF (Heating Seasonal Performance Factor)
of 9.10 in the heating mode or a maximum standard
S.E.E.R. (Seasonal Energy Efficiency Ratio) of 14.00 in the
cooling mode.
The following additional features, plus its energy-saving
characteristics, make the RPNE- Heat Pump outdoor unit
an excellent choice for new construction or upgrading your
present system.
Attractive, louvered wrap around jacket protects coil from
I
weather extremes and yard hazards. Top grille is steel
reinforced for extra strength. Cabinet is powder painted
for all weather protection.
Four sided outdoor coil design allows compressor opera-
I
tion with access panel removed.
Air is discharged upward away from bushes and shrubs.
I
The discharge pattern of the top grille provides minimum
air restriction, resulting in quiet fan operation.
Combination Grille/Motor Mount secures the fan motor to
I
the underside of the discharge grille.
All controls are accessible by removing one service
I
panel. Removable top grille provides access to the out-
door fan motor and outdoor coil.
Compressor compartment offers additional protection
I
from the elements and reduces operating noise.
Single speed, 8-pole fan motor is designed for quieter,
I
energy-saving operation.
Non-cycling reversing valve and demand defrost.
I
All models meet or exceed a 1000-hour salt spray test per
I
ASTM B117 Standard Practice for Operating Salt Spray
Testing Apparatus.
(IN CERTAIN
MATCHED SYSTEMS)
FORM NO. P11-766 REV. 7
Supersedes Form No. P11-766 Rev. 6
®
Series RPNE- Heat Pump Outdoor

Advertisement

loading

Summary of Contents for Rheem Seven

  • Page 1 Nominal Sizes 1 to 5 Tons tions. They are designed to operate with Rheem indoor [5.28 kW] to [17.58 kW] units with cooling and heating capacities certified under the ARI Certification program.
  • Page 2: Model Number Identification

    036 = 36,000 BTU/HR [10.55 kW] Y = 575V-3-60 042 = 42,000 BTU/HR [12.31 kW] (4&5 TON ONLY) 048 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.58 kW] [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 3 (Model No. RXPZ-C01) Blower Time Delay Control—RXMD-C04—Time Delay Accessory is not required if the outdoor unit is matched with a Rheem furnace or air Outdoor Thermostats— handler, or if the furnace or air handler used has a blower off time RXPT-A01—One outdoor thermostat in box.
  • Page 4: Scroll ® Compressor

    Rheem Heat Pump System For all season home comfort, performance and energy conservation, choose a Rheem RPNE- Series Heat Pump and a RHSA, RHLA, or RHKA Series Air Handler. More than a reverse cycle air conditioner, it’s a specially designed combination Winter/Summer comfort system using a single indoor coil for heating and cooling.
  • Page 5 [4.2] 23,400 16,850 6,550 22,600 14,400 RCFA-H*2417A* 11.35 13.00 3.36 2.30 8.30 [6.9] [4.9] [1.9] [330] [6.6] [4.2] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 6 21,250 8,950 1,000 33,000 20,600 RCFA-H*3621A* (RGLR-07?BRQ?) 12.10 13.50 3.60 2.54 8.75 [8.8] [6.2] [2.6] [472] [9.7] [6.0] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 7 23,850 10,550 1,150 37,200 23,800 RCHJ-36A1 (RGFD-09?ZCM?) 11.60 13.00 3.66 2.60 8.20 [10.1] [7.0] [3.1] [543] [10.9] [7.0] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 8 26,900 9,900 1,225 37,400 23,800 RCFA-H*3621A* (RGLR-07?BRQ?) 11.90 13.50 3.62 2.54 8.85 [10.8] [7.9] [2.9] [578] [11.0] [7.0] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 9 35,400 24,950 10,450 1,175 38,000 24,200 RCFA-H*3621A* 11.10 13.00 3.50 2.46 8.40 [10.4] [7.3] [3.1] [554] [11.1] [7.1] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 10 25,450 10,550 1,225 37,400 23,800 RHKA-HM3617 (RCSA-H*3617A*) 11.80 13.50 3.62 2.54 8.80 [10.5] [7.5] [3.1] [578] [11.0] [7.0] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 11 29,150 11,850 1,400 40,500 25,800 RHLA-HM4821 (RCSA-H*4821A*) 11.60 13.50 3.64 2.58 8.75 [12.0] [8.5] [3.5] [661] [11.9] [7.6] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 12 33,000 14,000 1,500 45,000 29,000 21AHLA48HM (RCSA-H*4821A*) 11.40 13.00 3.58 2.56 8.50 [13.8] [9.7] [4.1] [708] [13.2] [8.5] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 13 40,050 16,450 1,750 58,000 32,800 RHSA-HM6024 (RCSA-H*6024A*) 10.45 12.00 3.50 2.30 8.50 [16.6] [11.7] [4.8] [826] [17.0] [9.6] ➀ Highest sales volume tested combination required by DOE test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 14: Electrical And Physical Data

    3 SIDES Model Number Height “H” Length “L” Width “W” RPNE- (Inches) [mm] (Inches) [mm] (Inches) [mm] 19 [482] [1028] [701] 19 [482] [1127] [800] 29 [736] [1127] [800] 036/042/048/060 33 [838] [1127] [800] Rheem Heating, Cooling and Water Heating...
  • Page 15 0.93 0.93 0.94 0.94 0.96 0.96 Optional — 0.95 0.95 — 0.96 — — NOTES: *Standard line size N/A - Line size not recommended due to inadequate oil return. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating...
  • Page 16 Federal, State, Provincial, and Local codes, regulations, and practices. P.O. Box 17010, Fort Smith, AR 72917 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 4-08 DC FORM NO.