Return Valve; Suction Valve - Rheem Raypak 2450 Installation And Operation Manual

Heat pump pool & spa heater
Table of Contents

Advertisement

Item
Voltage
Up/ Down
for More
Voltage
Coil Temp
Amb Temp
Suct Temp
EXV Temp
Sat Temp
Water Temp
Installer
Menu
Pump Operation
Pump Heat
Valve Operation

Return Valve

Position 1 =

Suction Valve

Position 1 =
AUX Mode
Default
Range
Value
View Only – VAC
View Only –
degrees F or C
View Only –
degrees F or C
View Only –
degrees F or C
View Only –
degrees F or C
View Only –
degrees F or C
View Only –
degrees F or C
Yes or No
No
4-Speed Enabled,
Variable Enabled,
Disabled
Disabled
Enabled, Disabled
Disabled
Pool/Spa
Pool
Pool/Spa
Pool
AUX OFF, AUX
AUX
OUTPUT, REMOTE
OFF
OUT, EXT HEAT
(Continued on next page)
Access
Level
Press UP or DOWN buttons to access
Installer/
additional temperature measurements.
Service
Displays the 24VAC voltage as measured by
Installer/
the control board.
Service
Installer/
Displays the coil temperature sensor value –
used for defrost operation.
Service
Displays the ambient temperature sensor
Installer/
value – used for Outside Lockout operation
Service
and defrost.
Displays the suction line temperature sensor
Installer/
value – used for EXV operation ONLY. Will not
Service
be shown if EXV Disabled is selected.
Displays the EXV temperature sensor value –
ONLY available with EXV Enabled AND EXV
Installer/
Temp Sensor utilized. NOTE: This is ONLY
Service
utilized when the pressure transducer is NOT
used.
Displays the pressure transducer converted to
Installer/
a temperature. It is displayed whenever EXV
Service
is enabled.
Installer/
Displays the water temperature sensor value –
Service
used for temperature operation.
Select YES and press the MENU button
to gain access to additional programming
selections in this Installer/Service Sub-menu.
Select No and the next MENU button press
returns to the Set Current Time screen.
Installer/
If pump control through the heater is desired,
Service
select the appropriate pump mode – 4-Speed
Sub-
Enabled for discrete speed control or Variable
menu
Enabled for PWM control of pump.
Installer/
This feature selects the Digital input (pump
Service
speed) for the pump to operate during heater
Sub-
operation.
menu
This feature allows control of 3-way valves.
Installer/
Disabled is the default. When Enabled, the
Service
control will seek information as to whether the
Sub-
Return and Suction valves should be positions
menu
for Pool or Spa positions for each pump
period.
Installer/
See description of auxiliary mode operation on
Service
page 30.
Sub-
menu
Description
27