User Modes - Rheem Raypak 2450 Installation And Operation Manual

Heat pump pool & spa heater
Table of Contents

Advertisement

If the membrane switch remains inactive for 180 seconds
(3 minutes), the screen will revert to the current view.
On HEAT ONLY and POWER DEFROST models, the
options available by pressing the MENU/SET (MENU)
button are POOL HEAT, SPA, TIMED SPA and OFF.
On HEAT/COOL models, the options available by pressing
the MENU/SET (MENU) button are POOL HEAT, POOL
COOL, POOL AUTO, SPA, TIMED SPA and OFF. The
cooling setpoint can be adjusted in the range of 50°F
(10°C) to the Cooling Deadband value below the heating
setpoint. This allows use in Plunge Pools. Adjust the
cooling setpoint accordingly.
Upon initial application of power, the heater control briefly
sets all segments on the LCD at power-up. On a normal
power-up, the control displays the current software revision
and the model type configuration (HEAT ONLY, POWER
DEFROST or HEAT/COOL) on the LCD for 2 seconds
and then resumes the user-selected mode it was in before
power was interrupted.
Setpoints are read from non-volatile memory. If the self-
diagnostic check indicates corrupted values, "EEPROM
Fault" is displayed on the LCD and operation is prohibited
until setpoints are manually set.
If unit type has not been set (like during the replacement of
the control), the control prompts the user to set the model
type (HEAT ONLY, POWER DEFROST, or HEAT/COOL)
before any device operation is enabled.
Upon initial installation, there are several items that
must be defined and programmed depending on the
configuration and accessories intended to be controlled by
the control. These include: (1) Pump control (Yes or No
and then what type of control – 4-speed control or variable-
speed control), (2) 3-way valve control (Yes or No), and (3)
Auxiliary control (Yes or No and then what type – External
Heat, Auxiliary Output or Remote Output).
Once these choices are made, then additional information
relating to the establishing of pump periods, pump speeds
during each period and Return/Suction Valve positions
during each period must be determined and set in the
control.
The options for the control can be very simple or very
detailed, depending upon the needs of the installation.
Once programming is completed, the control is ready for
operation.
The user may select one of several operating modes. Each
mode is selected by pressing the MENU (button is labeled
MENU/SET, but MENU is used in these instructions for
simplicity) button to cycle between the modes. Each press
of the MENU button selects the next mode. There is no
automatic increment from continually pressing the MENU
button. In fact, continually pressing the MENU button (for
3+ seconds) will move the user into the USER Menu.

9. USER MODES

For HEAT ONLY and POWER DEFROST models, the
mode selections are:
OFF – POOL HEAT – SPA – TIMED SPA.
On HEAT ONLY and POWER DEFROST models, there
are additional operational modes available as noted below:
1. When POOL HEAT mode is selected, each press of
the UP or DOWN buttons will increase / decrease the
pool heating setpoint temperature. Holding the UP or
DOWN buttons down will speed up the change of the
temperature values.
2. When SPA mode is selected, each press of the UP
or DOWN buttons will increase / decrease the spa
setpoint temperature. Holding the UP or DOWN
buttons down will speed up the change of the
temperature values.
3. When TIMED SPA mode is selected, the display will
read "Up or Dn to Set". This tells the user to press
the UP or DOWN buttons to set the desired length of
time for the timed SPA heating operation. Pressing
the UP button will increase the timer in 15-minute
increments (up to 6 hours maximum). Pressing the
DOWN button will decrease the timer by 15-minute
increments. The timer will start and the unit will begin
heating as necessary to maintain the Spa setpoint
temperature for this timer duration. At the end of the
timed period, the unit will automatically return to the
last operational state (POOL HEAT, POOL COOL,
POOL AUTO, SPA, or OFF) of the control. Once
the unit turns on, the display will toggle between
the current Spa water temperature and the current
operating state ("Heating" for example). Pressing
the MENU button will change the display to show the
time remaining on the timer. Press the MENU button
again to go back to the current status.
For HEAT/COOL models, the mode selections are:
OFF – POOL HEAT – POOL COOL – POOL AUTO –
SPA – TIMED SPA.
On HEAT/COOL models, there are additional operational
modes available as noted below:
1. When POOL HEAT mode is selected, each press of
the UP or DOWN buttons will increase / decrease the
pool heating setpoint temperature. Holding the UP or
DOWN buttons down will speed up the change of the
temperature values.
2. When POOL COOL mode is selected, each press of
the UP or DOWN buttons will increase / decrease the
pool cooling setpoint temperature. Holding the UP or
DOWN buttons down will speed up the change of the
temperature values.
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents