Download Print this page

Festo VIFB8-03 Series Brief Description page 12

Fieldbus node 8 for valve terminal

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
2
Configuration
Please note
The cover is connected to the internal PC boards via the
operating voltage cable. It cannot therefore not be re
moved completely.
Caution
The components of the valve terminal contain elements
which are liable to damage by electrostatic charges.
The components can also be destroyed if the contact
surfaces of plug connectors are touched, or if the re
gulations for handling electrostatically vulnerable com
ponents are not observed.
Please observe the following when configuring:
1. Switch off the operating voltage.
2. Open node (screws are liable to be lost).
3. Set fieldbus address.
4. Set fieldbus baud rate.
5. Close node.
6. If the valve terminal to be connected is at the end of a
fieldbus line, a terminating resistor must be installed.
12
Festo VIFB8−..− 0208a English

Advertisement

loading

This manual is also suitable for:

Vifb8-05 series