Output Signal Setting - Mitsubishi Electric FR-A7AY E kit-SC Instruction Manual

Inverter plug-in option
Hide thumbs Also See for FR-A7AY E kit-SC:
Table of Contents

Advertisement

4.5.3

Output signal setting

Set the output signals to be monitored. Set Pr. 306 to output the same signal from terminals AM0 and AM1
and Pr. 306 and Pr. 310 to output different signals. For details of signal definitions, refer to Pr. 54 and Pr. 158
of the inverter instruction manual.
Pr. 306/Pr. 310
Setting
1
Output frequency
2
Output current
3
Output voltage
5
Frequency setting
7
Motor torque
8
Converter output voltage
9
Regenerative brake duty
10
Electronic thermal relay function load factor
11
Output current peak value
12
Converter output voltage peak value
14
Output power
21
Reference voltage output
24
Motor load factor
52
PID set point
53
PID process value
61
Motor thermal load factor
62
Inverter thermal load factor
Types of Monitor
EXTENSION ANALOG OUTPUT
Increments
Full-Scale Value
0.01Hz
Pr. 55
0.01A
Pr. 56
200V class : 400V
0.1V
400V class : 800V
0.01Hz
Pr. 55
Rated torque of the applied motor × 2
0.1%
200V class : 400V
0.1V
400V class : 800V
0.1%
Pr. 70
0.1%
100%
0.01
Pr. 56
200V class : 400V
0.1V
400V class : 800V
Rated inverter power × 2
0.01kW
0.1%
200%
0.1%
100%
0.1%
100%
0.1%
Thermal relay operation level (100%)
0.1%
Thermal relay operation level (100%)
4
21