Large area sprinkler

Advertisement

3. Description 
 
Recommended operating pressure   5 to   7 bar 
Permissible operating pressure      4 to 10 bar 
 
                The pressure at the sprinkler must not exceed 10 bar. 
 
For further data please refer to the separate data leaflet. 
 
4.   A ssembly 
 
 Threaded connection on the sprinkler is 2½" female thread. 
 For  sealing  the  thread,  hemp  and  a  jointing  compound  has  to  be  used  e.g.  Fermit 
special 
 To screw on the sprinkler, always use a pipe wrench size 3". 
Tighten the sprinkler with around 30Nm. 
 
 
 
Pipe wrench 3" 
Screw  on  the  connection  socket  up  to  the  detent,  so  that  the  sprinkler  cannot  unscrew 
itself during operation. 
TDP057e.doc 
 
Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany 
                                                                 Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 
Do not turn the sprinkler by using the jet pipe. 
  S prinklers should be installed above head‐height, respectively adopt any 
alternative safety measures.  
 
Rev. 22.10.2014 
    E‐mail: 
perrot@perrot.de / E‐mail Technical Department: technik@perrot.de 
picture1 
Page 4 / 11 