Hazards of ignoring safety instructions Failing to heed the safety instructions may result in danger to life and limb, harm to the environment and/or damage to the device. Failing to heed the safety instructions may lead to the loss of any right to claim compensation. TDP062e.doc Rev. 02.06.2014 Page 3 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Slowly open water supply to the valve until operating pressure is present. The sprinkler may briefly open but should then close automatically after no more than 30 seconds. d) Once the water supply is open and the maximum operating pressure has been reached, check sprinkler and connection for leaks. e) Check sprinkler is working flawlessly: Open sprinkler using ‘Manual opening’ by turning the screw for ‘Manual opening’ to the position between AUTO and OFF (approx. 1 revolution). Sprinkler head rises and begins to rotate. Do not stand facing the nozzle opening! Set desired output pressure by turning the ‘Pressure regulator screw’ to the right (‐) as far as it will go (minimum pressure). The output pressure is now set to approximately 3 bar. If you turn the ‘Pressure regulator screw’ one complete revolution to the left (+), the output pressure will go up by 1 bar. f) Close ‘Manual opening’ and put in the AUTO position (see point 5b). Sprinkler should stop the throughflow of water within 30 seconds. g) Perform steps e) and f) again repeatedly until this functions are flawlessly. h) Check again that the sprinkler is working correctly by starting it electrically from the control module. TDP062e.doc Rev. 02.06.2014 Page 6 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Electrically activate the solenoid several times so that any residual water is pushed out of the coil cavity. During winter time it is recommended to activate the solenoid for about 1 minute 2 times per week. This model does not have a discharge valve and can therefore not be emptied the traditional way by gravity. Setting irrigation sector (Part‐circle sprinklers only) Set the left side stop position using: Left stop position can be adjusted by +/‐ 90° Note: One complete revolution of the adjuster screw adjusts the sector stop position by 60° TDP062e.doc Rev. 02.06.2014 Page 7 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Page 8
Set right side stop position using: Right stop position can be set to a watering sector of 30° to 330°. Note: The sprinkler has a factory setting of 180° TDP062e.doc Rev. 02.06.2014 Page 8 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Page 9
Note: In order to speed up the setting of the irrigation sector, the sprinkler head can be manually turned forward with the rotating direction. . DO NOT TURN BACK! the factory setting of the right sector stop is according this sketch Right stop Left stop position position TDP062e.doc Rev. 02.06.2014 Page 9 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Replacing the nozzle Ensure sprinkler is not under pressure. Using a big screwdriver, unclip the lid Using a screwdriver, remove white retaining ring. Guide groove for lid dismantling Retaining ring Retaining ring Pull sprinkler insert out of the housing Push down the flange and secure the head with the retainer TDP062e.doc Rev. 02.06.2014 Page 10 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Page 11
Take off sprinkler head cover by levering the cover up at the notch using a small screwdriver. Rotate nozzle to the left using pliers and then pull out. Optionally the sprinkler can be assembled with a tail nozzle. This nozzle can be refitted or/and also closed with a corresponding plug. Put O‐ring over the new nozzle O‐Ring Nozzle and, reversing the procedure, re‐install in the sprinkler head. Fit cover into sprinkler head’s snap‐in connection by first pushing it as far as it will go against the side opposite the nozzle and then snapping it completely into place on the nozzle side. TDP062e.doc Rev. 02.06.2014 Page 11 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Snap inlet nozzle back onto the sprinkler module so that the elongated rib is pointing to the nozzle diameter being used. Strainer Inlet nozzle Inlet nozzle White for Hydra XS 4 Black for Hydra S + Hydra XS 5+6 Rib for Hydra M Turbine View from above Rib Sprinkler insert Note: If you want a higher rotational speed, the rib must be pointing to a smaller diameter than that of the nozzle actually being used. TDP062e.doc Rev. 02.06.2014 Page 12 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Ensure correct alignment. Sprinkler insert Guide housing Guide ribs Push flange down as far as it will go. Fit retaining ring. Retaining ring must be fully inserted into the slot. Unclip snap‐fit lid from the housing. Check sprinkler is working properly as per point’s 5b‐5f. TDP062e.doc Rev. 02.06.2014 Page 13 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Valve insert removal / installation Ensure sprinkler is not under pressure. Using a big screwdriver, unclip the lid Using a screwdriver, remove white retaining ring Retaining ring Retaining ring Hollow screw Pull sprinkler insert out of the housing Taking out the valve Take off retaining ring by help of retaining ring lifter (see chapter 4). Screw valve lifter / coarse filter wrench onto valve insert’s studs and manually tighten. Pull out valve insert complete with valve lifter and unscrew. Valve insert is now held on hollow screw by O‐ring only. TDP062e.doc Rev. 02.06.2014 Page 14 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Take off flushing equipment. Ensure that thread and O‐ring are clean. Lightly smear O‐ring with acid‐free grease. Put coarse filter in place and manually tighten using coarse filter wrench. Fitting the valve Before fitting the valve, check the valve insert – especially around the valve seat – for any dirt or damage! Screw cleaned or new valve insert onto the valve lifter again and fit into the sprinkler housing. Ensure it is fitted in the correct position! Hollow screw Entry for hollow screw TDP062e.doc Rev. 02.06.2014 Page 16 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
Fit retaining ring. Retaining ring must be fully inserted into the slot. Clip in snap‐fit lid. Check sprinkler is working properly as per points 5b ‐ 5e. Control unit removal / installation Ensure sprinkler is not under pressure. Taking out the control unit Using a big screwdriver, unclip the lid Unclip control unit from protective casing and lift up. Twist out coil. When replacing the control unit, cut off the hoses as close as possible to the unit’s nozzle. Control unit Sprinkler TDP062e.doc Rev. 02.06.2014 Page 18 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
the sprinkler will not work. Screw in coil. Clip control unit into protective casing. Using a big screwdriver, clip off the snap‐fit lid. Check sprinkler is working properly as per points 5b – 5f. 10 Removal / fitting of manual opening and pressure regulating inserts Ensure sprinkler is not under pressure. 10.1 Removal of manual opening and pressure regulating inserts Using a big screwdriver, unclip the snap fit lid from the housing. Unclip control unit from protective casing and lift up. Using an SW19 flat spanner, twist out manual opening and pressure regulator screws. Control unit Coil TDP062e.doc Rev. 02.06.2014 Page 19 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
10.2 Fitting manual opening and pressure regulating inserts Set manual opening to Auto and pressure regulator into the minus (‐) position (turn to the left as far as it will go) and screw in using an SW19 flat spanner. Clip control unit into protective casing. Unclip the snap fit lid from the housing. Check sprinkler is working properly as per points 5b – 5f. Set manual opening / pressure regulator screws to desired position. 11 Maintenance Cut sprinkler housing free of any overgrowing grass. It makes sense to do this work with the cut off tool before starting up the system in spring. TDP062e.doc Rev. 02.06.2014 Page 20 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
O‐ring at coarse filter damaged Exchange O‐ring and seal with teflon tape Inlet nozzle incorrectly set (see Set inlet nozzle to correct chapter 7) nozzle diameter Rotary speed too Turbine blocked by stones or bits Clean turbine low/ too high or does of dirt not rotate at all Inlet nozzle or filter have worked Clip parts together again loose Stones and bits of dirt are Clean valve and flush sprinkler Output pressure at hindering an unimpeded flow‐ sprinkler nozzle too through of water low or casting range Pressure regulator in minus (‐) Turn pressure regulator screw too short position to the left towards (+) Subject to change without prior notice. TDP062e.doc Rev. 02.06.2014 Page 21 / 21 Perrot REGNERBAU CALW GmbH Industriestraße 19‐29 / D‐75382 Althengstett / Germany Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 E‐mail: perrot@perrot.de / E‐mail Technical Department: technik@perrot.de ...