Perrot Hydra M Maintenance And Operating Instructions

Pop-up sprinkler

Advertisement

Quick Links

Maintenance and Operating Instructions 
 
TDP078e.doc 
 
Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany 
                                                                 Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133 
Pop‐up Sprinkler 
Hydra M (W,D)‐H‐TC
PERROT 
Rev. 30.11.2016 
   E‐mail: 
p
errot@perrot.de / E‐mail Technical Department: technik@perrot.de 
 
  
 
Page 1 / 16 

Advertisement

Table of Contents
loading

Summary of Contents for Perrot Hydra M

  • Page 1 Maintenance and Operating Instructions    Pop‐up Sprinkler    Hydra M (W,D)‐H‐TC      PERROT  TDP078e.doc  Rev. 30.11.2016  Page 1 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 2: Table Of Contents

    SETTING IRRIGATION SECTOR  .........................  7     REPLACING THE NOZZLE ........................  1 0       ........................ 12 DJUSTING THE INLET NOZZLE       ........................ 13 ITTING THE SPRINKLER INSERT     MAINTENANCE ............................  1 4     TROUBLESHOOTING  ..........................  1 4   TDP078e.doc  Rev. 30.11.2016  Page 2 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 3: Safety

                                                      Hazards of ignoring safety instructions    Failing  to  heed  the  safety  instructions  may  result  in  danger  to  life  and  limb,  harm  to  the  environment and/or damage to the device.  Failing to heed the safety instructions may lead  to the loss of any right to claim compensation.    TDP078e.doc  Rev. 30.11.2016  Page 3 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 4: Description

      Description  View from above    Nozzle direction  Plug for cover  fastening screw      Side view  Sprinkler head cover  with sod cup    Housing cover for  sod cup  Guide housing  TDP078e.doc  Rev. 30.11.2016  Page 4 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 5: Installation

          is aligned in a straight line from the left side of the irrigation sector.   A dot is located on the border of the housing cover with sod cup as an additional  identification mark.    Dot   Alignment   Left side of irrigation sector      Special tools    Retainer for sprinkler head  Changing nozzle  RT14031  Hydra L/M/S    Flushing equipment  Hydra M  Flushing pipes  RT14934    Wrench for changing nozzles   Changing nozzles   ZB98276    TORX‐key    for screw at the lid   ZB98289      TDP078e.doc  Rev. 30.11.2016  Page 5 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 6: Commissioning / Preparing For Winter

      Commissioning    a)    Slowly open water supply to the sprinkler until operating pressure is present.    b)   Once the water supply is open and the maximum operating pressure has been  reached, check sprinkler and connection for leaks. Sprinkler head rises and begins to  rotate.                   Do not stand facing the nozzle opening!        Preparing for winter   Before the onset of any winter frosts, the sprinkler needs to be emptied. To do this, a  powerful compressor needs to be attached to the pipeline network. Then open the  solenoid valve in front of the sprinkler and keep it opens until nothing but air comes  out of the nozzle.      This model does not have a discharge valve and can therefore not be  emptied the traditional way by gravity.     TDP078e.doc  Rev. 30.11.2016  Page 6 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 7: Setting Irrigation Sector

    Setting irrigation sector  (Part‐circle sprinklers only)    Since the irrigation sector adjustment screws are located under the cover with sod cup  on the Hydra M‐TC version, the cover must be disassembled to make irrigation sector  adjustments.  First remove the plug and then the coder fastening screw using a Torx‐key TX20.  Cover  fastening  screw      Then the sprinkler head cover with sod cup can be unsnapped by pressing it lightly  rearward.    Left stop position can be adjusted by +/‐ 90°      Note:   One complete revolution of the  adjuster screw adjusts the sector   stop position by 60°    Right‐side stop                 Left‐side stop TDP078e.doc  Rev. 30.11.2016  Page 7 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 8    Set right side stop position:       Right stop position can   be set to a watering sector of 30° to 330°.                  Note:  The sprinkler has a factory setting of 180°  TDP078e.doc  Rev. 30.11.2016  Page 8 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 9     Note:   In order to speed up the setting of the irrigation sector, the sprinkler head can  be manually turned forward with the rotating direction. .  DO NOT TURN BACK!             the factory setting of  the right sector stop is  according this sketch  Right stop  Left stop position  position            TDP078e.doc  Rev. 30.11.2016  Page 9 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 10: Replacing The Nozzle

      Replacing the nozzle    Ensure sprinkler is not under pressure.       Disassemble housing cover with sod cup by unscrewing the three (3) sheet metal  screws (item 1) using a Torx‐key.   Pull the cover off in an upward direction   Disassemble sprinkler head cover with sod cup by unscrewing the central cover  mounting screw (item 2).   Now the sprinkler head cover with sod cup can be unsnapped by pressing it lightly  rearward (see also photo on next page).   Remove white lock washer using screwdriver  Pos.1 Pos.2  Retaining ring                       Pull sprinkler insert out of the housing   Push down the flange and secure the head with the retainer                             TDP078e.doc  Rev. 30.11.2016  Page 10 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 11  Rotate nozzle to the left using pliers and then pull out.   Optionally the sprinkler can be assembled with a tail nozzle. This nozzle can be  refitted or/and also closed with a corresponding plug.   Put O‐ring over the new nozzle    O‐Ring Nozzle              and, reversing the procedure, re‐install in the sprinkler head.     Fit cover with sod cup into sprinkler head’s snap‐in connection by first pushing it as  far as it will go against the side opposite the nozzle and then snapping it completely  into place on the nozzle side.                                                  Using a Torx‐key, tighten the cover fastening screw (item 2) of the cover with sod cup  and plug it.    TDP078e.doc  Rev. 30.11.2016  Page 11 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 12: Adjusting The Inlet Nozzle

     Snap inlet nozzle back onto the sprinkler module so that the elongated rib is pointing  to the nozzle diameter being used.          Strainer   Inlet nozzle  Rib  Inlet nozzle White  for Hydra XS 4  Black for Hydra S + Hydra XS 5+6  Turbine for Hydra M    View from above Rib  Sprinkler  insert                                Note:  If you want a higher rotational speed, the rib must be pointing to a smaller  diameter than that of the nozzle actually being used. TDP078e.doc  Rev. 30.11.2016  Page 12 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 13: Fitting The Sprinkler Insert

    Sprinkler     insert    Guide housing                         Guide ribs         Push flange down as far as it will go.   Fit retaining ring.                             Retaining ring must be fully inserted into the slot.     Assemble cover with sod cup by mounting the cover on the guide housing such that  the    mark of the guide housing and cover are at the same position. Tighten the  cover with three (3) sheetmetal screws (item 1).   Check sprinkler is working properly as per point’s 5a‐5b.      TDP078e.doc  Rev. 30.11.2016  Page 13 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 14: Maintenance

    Cause  Remedy  Stop valve fails to close  Bits of dirt between sealing plate  Clean stop valve seat and  completely   and stop valve.  sealing plate  Rotary speed too low / too high  Inlet nozzle incorrectly set (see  Set inlet nozzle to correct  or does not rotate at all  chapter 7)  nozzle diameter  Turbine blocked by stones or bits  Clean turbine  of dirt  Inlet nozzle or filter have worked  Clip parts together again  loose  Output pressure at sprinkler  Stones and bits of dirt are  Clean stop valve and flush  nozzle too low or casting range  hindering an unimpeded flow‐ sprinkler  too short  through of water        Subject to change without prior notice.   TDP078e.doc  Rev. 30.11.2016  Page 14 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 15 Notizen / Notes TDP078e.doc  Rev. 30.11.2016  Page 15 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...
  • Page 16                                   Für weitere Informationen stehen wir Ihnen gerne zur Verfügung. We remain at your full disposal for any further information you may require!            REGNERBAU CALW GmbH  Industriestrasse 19‐29  75382 Althengstett / Germany  Tel. +49 / 7051 / 162‐0  Fax. +49 / 7051 / 162‐133  http://www.perrot.de      TDP078e.doc  Rev. 30.11.2016  Page 16 / 16    Perrot REGNERBAU CALW GmbH     Industriestraße 19‐29  /  D‐75382 Althengstett / Germany                                                                   Phone: 0049‐7051‐162‐0 / Fax: 0049‐7051‐162–133     E‐mail:  errot@perrot.de / E‐mail Technical Department: technik@perrot.de ...

This manual is also suitable for:

Hydra d-h-tcHydra w-h-tc

Table of Contents