User's Manual | ACOM 1000 | HF + 6m Linear Amplifier
7.2. Functions
a)
Antenna Impedance Matching Process: plate-load True Resistance Indicator (TRI) aided;
b)
T/R System: QSK operation with built-in, vacuum RF antenna relay (special quiet installation)'
c)
Protections:
Cover interlock for operator's safety;
•
Inrush power-on current control;
•
High voltage, control grid, screen grid, and plate currents;
•
Exhaust air temperature;
•
T/R sequencing;
•
Antenna relay contacts, including RF power induced in antenna from another nearby
•
transmitter;
Antenna matching quality;
•
Reflected power;
•
RF arcs, including in antenna system;
•
Overdrive;
•
d)
Signatures of the amplifier internal status are stored in a nonvolatile memory for the seven
most recent auto protection trips;
e)
Dot matrix backlighted alphanumeric OLED with bar graph for forward peak power and text
messages to the operator;
f)
Measurement and constantly monitoring of 12 most important parameters of the amplifier
via OLED;
g)
Tube: a single 4CX800A (GU74B) high-performance ceramic-metal tetrode of Svetlana with
plate dissipation of 800W, grid driven, forced air-cooling.
August 2020