Turning The System On Or Off And Keypad Commands For B920/B930; Turning The System On And Off; Turning All On (Arming); Turning Off (Disarming) - Bosch D9412GV4 Quick Reference Manual

V2.03
Hide thumbs Also See for D9412GV4:
Table of Contents

Advertisement

22
en | Turning the System ON or OFF and Keypad Commands for B920/B930
9
Turning the System ON or OFF and Keypad Commands
for B920/B930
9.1

Turning the System On and Off

9.1.1

Turning All On (Arming)

Enter the passcode and [Enter] or [ENTER] to turn on (arm) all areas where the user has
authority and are areas within the scope of the keypad.
9.1.2

Turning Off (Disarming)

Enter the passcode and [Enter] or [ENTER] to turn off (disarm) all areas where the user has
authority and are areas within the scope of the keypad.
9.1.3

Set Duress +1 Using RPS

1.
2.
3.
9.2

Keypad Commands

Function
All On (Turns on [arms] the
current area with delay)
All On, Instant
Part On, Instant
Part On (with delay)
Watch
See Alarms
Reset Sensors
Extend Close
Bypass
Unbypass
Table 9.1: Keypad Commands
*Supported by B920/B930 keypads only.
9.2.1

Legacy Keypads: D1255, D1260, D1265

If your system includes D1255, D1260, or D1265 legacy keypads, you can initiate the
commands described in the previous table from those keypads. These are the only commands
available from those keypads.
2014.05 | 05 | F.01U.265.463
Go to PANEL WIDE PARAMETERS→Miscellaneous→Duress Type. Select 1.
Go to AREA WIDE PARAMETERS→Area Parameters→Duress Enable. Select YES.
Go to User Interface→Authority Levels. In the authority levels to be used, select E for the
Send Duress parameter.
Quick Reference Guide
Command
CMD 1
CMD 1 1
CMD 2
CMD 3
CMD 6
CMD 4 0*
CMD 4 7
CMD 5 1
CMD 0
CMD 0 0
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv4

Table of Contents