Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Use the following procedure to verify that a recorded program matches
the program in the memory of the PLC-4 Microtrol programmable
controller.
1.
Install the recorder as described in chapter 3.
2.
Set the BAUD RATE switch to 1200 baud. Select the track
containing the desired program.
3.
Set the power ON/OFF switch to the On position.
4.
Insert a data cartridge into the recorder.
5.
Wait for the recorder to complete the repacking operation .
6.
Type [AUX FUNC][4][2] on the 1770-T12 programmer.
7.
Wait until the 1770-T12 programmer displays the message:
TAPE VERIFY
COMPLETE
8.
Type [CLEAR] on the 1770-T12 programmer to terminate the verify
function.
When recording Series 7100 CNC programs through an industrial
terminal system, use the following procedure:
1.
Install the recorder as described in chapter 3.
2.
Set the BAUD RATE switch to 1200 baud. Set the TRACK
SELECT switch to track 1 or track 2.
3.
Set the power ON/OFF switch to the ON position.
4.
Be sure that the write protect tab on the data cartridge is positioned
to the left, and insert a data cartridge into the recorder.
5.
Wait for the recorder to complete the repacking operation .
6.
Place the mode select switch on the programmable interface (PI)
module in the LOAD (up) position.
7.
Place the cursor on the first program instruction.
8.
Press [RECORD][0] on the industrial terminal keyboard.
9.
Press the RECORD ON TAPE pushbutton.
10. Wait for the RECORD ON TAPE indicator to turn off and for the
tape to stop.
11. Press the STOP/REWIND pushbutton.
12. Wait for the tape to completely rewind.