230 V Fuse Kit - Allen-Bradley 1770-SB User Manual

Data cartridge recorder
Table of Contents

Advertisement

Chapter 2
Recorder Hardware

230 V Fuse Kit

2 2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 2.A
Data Cartridge Recorder Switches
Name
POWER ON/OFF
BAUD RATE
TRACK SELECT
READ FROM TAPE
RECORD ON TAPE
STOP/REWIND
Table 2.B
Data Cartridge Recorder Indicators
Name
POWER
STOP/REWIND
BOTH TRACKS USED
END OF TRACK
DATA IN
DATA ERROR
DATA OUT
RECORD ON TAPE
WRITE INHIBITED
READ FROM TAPE
The data cartridge recorder includes a 230V AC fuse kit for conversion to
230V AC operation. The fuse kit includes:
Instructions for converting to 230V AC operation
A 230V, 0.25A fuse
A 230V AC label
The recorder does not come with a 230V AC power cord. Therefore, the
power cord must be changed for 230V AC operation.
Function
Toggle switch. Turns recorder power on or off.
Rotary switch. Selects 300, 600, 1200, 2400, 4800 or 9600 baud
operation.
Rotary switch. Selects track 1, track 2, or continuous operation.
Momentary action pushbutton switch. Puts the recorder into the READ
mode.
Momentary action pushbutton switch. Puts the recorder into the
WRITE mode.
Momentary action pushbutton switch. Used to exit READ or WRITE
mode. When the tape is stopped, the switch initiates a rewind to the
Beginning Of Tape (BOT) mark.
Indication
Power is applies to the recorder and the toggle switch is in the ON
position.
Tape is repacking or rewinding.
TRACK SELECT switch is in CONT position and current operation
(READ, WRITE or IDLE) is on track 2.
Tape has reached the end of track 1 or track 2. Illuminates between
tracks and at the end of track 2 in continuous operation.
Recorder is receiving data.
Recorder has failed an attempted operation.
Recorder is transmitting data.
Recorder is in the WRITE mode.
Data cartridge is protected. Data can not be recorded.
Recorder is in the READ mode.