5.
Wait for the recorder to complete the repacking operation .
6.
Verify that the size of the switch-selected data table in the PLC
memory is a least as large as the data table in the recorded program.
7.
Verify that the total memory capacity of the PLC programmable
controller is large enough to store the recorded program.
8.
Set the mode select keyswitch of the PLC to the PROGRAM LOAD
position.
9.
Set the switch on the cassette recorder interconnect cable to the
LOAD position.
10. Press the READ FROM TAPE pushbutton.
11. Wait for the READ FROM TAPE indicator to turn on, then off.
12. Press the STOP/REWIND pushbutton.
13. Set the switch on the cassette recorder interconnect cable to the
VERIFY AND RECORD position.
14. Press the READ FROM TAPE PUSHBUTTON.
15. If the ERROR indicator on the program panel interface module or
the on-line programming module illuminates, either locate and
correct the errors or repeat the load operation.