Function Selection
Dimensions (Check position)
[Side mounting]
2-Top/bottom
mounting brackets
2-Mounting holes
24
Intermediate
5.5
mounting bracket
36
43
6
Dimensions A to E and P
Model name
Number of beams
F3SJ-AM2P300
2
F3SJ-AM3P300
3
F3SJ-AM4P300
4
F3SJ-AM2P400
2
F3SJ-AM3P400
3
F3SJ-AM4P400
4
F3SJ-AM2P500
2
For dimensional drawing of mounting brackets other than those included in the product (F39-LJ1/F39-LJ3), refer to F3SJ-AM
series user's manual.
F3SJ-AM
Quick Installation Manual
Mounting/Beam Alignment
30
20
5.5
10
4-Mounting holes
6.5
2-Mounting holes
9
M12 Waterproof connector
53
A
394
366.5
694
666.5
994
966.5
494
466.5
894
866.5
1294
1266.5
594
566.5
Pre-Operation Checklist /
Maintenance Checklists
35
30
Beam center line mark
31
Beam
B
C
D
E
320
300
-
620
600
B/2
920
900
B/2
420
400
-
820
800
B/2
1220
1200
B/3
520
500
-
20
4-M5
31
2-M5
5
[ Unit : mm ]
Number of intermediate
P
mounting brackets
300
0
300
1
300
1
400
0
400
1
400
2
500
0
Step1
Check
position
Step2
Mount
Step3
Align
beams