Function Selection
5. Fix the unit on the wall.
Step1
Wall-mounting screw (M5)
Check
position
Backside mounting
Step2
Mount
Step3
Align
beams
Tightening with torque exceeding the recommended value too much may lead to a failure.
Wall-mounting screws are not included.
6. Align beams based on the indicators.
Please refer to instruction sheet about wiring examples.
Align the unit to the
center of the angle
where five (5) light
intensity level
indicators turn ON
Display Patterns of the Incident Light Level Indicator
ON
incident light level indicator
Safety Output
Incident light level
Operation is possible with incident light level of 100% or more, but to ensure stability, operate when all incident light level
indicators.
Please do not tighten each screw one by one. Fully tighten all of them in a balanced manner at all places.
The angle adjustment range of mounting bracket F39-LJ3 is +/-10 degrees.
9
Mounting/Beam Alignment
Tighten securely
(Recommended tightening torque: 0.54N•m)
OFF
O
N
O
N
Less than
170% or
170%
~
higher
130%
Pre-Operation Checklist /
Maintenance Checklists
Wall-mounting screw (M5)
Side mounting
Tighten securely
(Recommended tightening torque: 0.54N•m)
(Recommended tightening torque: 1.2N•m)
O
N
O
F
F
O
F
F
Less than
Less than
Less than
130%
100%
75%
~
~
~
100%
75%
50%
Tighten securely
O
F
F
Less than
50%
F3SJ-AM