Surface Vertical Rod
Exit Devices
Installation Instructions
3
Installation
a
Install Device
A. Mount trim (Follow instructions with trim).
B. Seat bar in place. Fasten device head (2 PRHMS or SNB). (Figure 13)
C. Set bar level. Locate end clamp holes.
D. Prepare end clamp mounting holes. Mount end clamp (2 #1/4-20 PRHMS or 3/8" (10 mm) dia. SNB).
E. Check slide action (Slide travel = 9/16" (14 mm)
• Depress touchbar (slide should move up). Release touchbar (slide should fall back to original rest
position).
• Activate trim (slide should move up). Release trim activator (slide should fall back to rest position).
• NOT FOR FIRE DEVICES - Depress touchbar, turn dogging key clockwise (bar must remain
depressed, slide must remain in up position). Turn dogging key counterclockwise (bar should
extend, slide should fall back to rest position).
F. Tighten all mounting screws.
b
Set Latches, Strikes, and Guides
Top Strike Detail for ED5400 Series
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2013, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
B
Device Screws
(Bolt to door reinforcement, sex nuts, or trim studs)
Shim (2 supplied)
(Start with one)
Strike plate
(Ridges face down)
Strike
(2) 10-24 x 5/8" MS or
(2) #10 X 1" WS (Flat Head)
Figure 14
Figure 13
Top Strike Detail for ED5470 Series
Strike angle must
engage strike
Figure 15
9
1-1/4"
C
(32 mm)
D
1/2"
(13 mm)
Top Stike
(2) 10-24 PFHMS
FM164 09/19