Timing Specification

Image data outputs are transferred with USB bulk transfer. Timing numerical value below is described by
absolute prerequisite that camera can use transmission band without restriction of other device. When there
is other device on the same bus, the value described below is not guaranteed.
● In normal shutter mode
ExposureActive
(GPIO Output)
Exposure
Sensor Output
USB Streaming
Model Name
BU302MG
Mono10, Mono12
BU505MG
Mono10, Mono12
Bayer8, Mono8
YUV411
BU302MCG
YUV422
Bayer10, Bayer12
RGB, BGR
Bayer8, Mono8
YUV411
BU505MCG
YUV422
Bayer10, Bayer12
RGB, BGR
Copyright © 2016 - 2020 Toshiba Teli Corporation, All rights reserved.
T0
Image
Image
T0
format
[μs]
Mono8
15.8
18.7
Mono8
18.9
22.3
15.8
18.7
18.9
22.3
Image
T1
Image
T2
T1
[ms]
8.1
9.6
12.9
15.3
8.1
9.6
12.9
15.3
26 / 101
Image
Imag e
T2
T3
T2
T3
[ms]
[s]
8.1
9.6
12.9
15.3
8.1
11.5
15.3
1/(Frame Rate setting)
15.3
23.0
12.9
18.4
24.6
24.6
36.8
DAA00609C