Page 1
Greeneville, TN 37743 U.S.A. Declare under our sole responsibility, that the Electronic Air Purification System Model: activTek INDUCT 5000 and activTek INDUCT 10000 to which this declaration relates, conforms with the following standards: EN55015-1:2005 EMC Requirements for Household Appliances and Similar...
Page 2
ELECTRoNIC AIR PURIfICATIoN SySTEM activTek Environmental 310 T. Elmer Cox Drive Greeneville, TN 37743 CAUTION: Read manual carefully for proper procedures and operation.
Please record the name and phone of your activTek Distributor: Name ____________________________________________________________________ Phone ____________________________________________________________________ Please record the serial number of your activTek INDUCT 5000/INDUCT 10000 by activTek: Serial # ___________________________________________________________________ This owner's manual covers both the activTek INDUCT 5000 single commercial probe unit and the activTek INDUCT 10000 dual commercial probe unit.
The ActivePure Cell (Advanced oxidation System) is designed to reduce odors, air pollutants, and other contaminants through a patent pending ActivePure process. When the activTek INDUCT system is in operation, the ActivePure Cell uses an Advanced oxidation Process to reduce airborne contaminants. The ActivePure Cell also has the added benefit of producing safe, low levels of ozone as a by-product of the ActivePure reaction.
PERIODIC MAINTENANCE The only periodic maintenance required for the activTek INDUCT 5000/INDUCT 10000 is replacement of the ActivePure Cell(s). operation of the ActivePure Cell(s) is indicated by the small indicator lamp(s) located on the bottom of the ballast cover (see diagram below).
2. The ductwork around the installation area should be clean and dry to insure proper connection. 3. Depending on model, one opening (activTek INDUCT 5000) or two openings (activTek INDUCT 10000) approximately 4” (four inches) (10.16 cm) in diameter will need to be cut into the existing duct work to install the unit properly.
It is recommended for maximum effectiveness that the unit be placed as close to the air handler as possible. PLEASE NOTE: The illustrations are shown installing an activTek INDUCT 10000. procedures shown in this manual apply to both units, unless otherwise indicated.
WARNING: Hard wiring unit into HVAC system should be done by a licensed HVAC installer or qualified electrical contractor only. 1. Connect wires coming from the activTek INDUCT 5000/INDUCT 10000 unit to the fan relay as follows: All units come standard with a blunt cord.
THE INDICATOR LAMPS ON THE BOTTOM OF THE uNIT HOuSING ONLY. Note: Disconnect power at the breaker or fuse panel before servicing unit. 1. Disconnect power at the breaker or 2. Remove the activTek INDUCT ballast fuse panel before servicing unit. assembly by removing the four (4) wing nuts and sliding the unit out.
(4) screws then removing cover. 3. Remove the two (2) nuts on the 4. Remove the wires (activTek top and bottom side of the ballast INDUCT 10000 - 8 wires, INDUCT to pull ballast from assembly.
REPLACING ThE BALLAST (CONTINUED) 5. Place new ballast into original 6. Return wiring to its original location and fasten the two (2) locations on the ballast. locking nuts into place. 7. Replace cover and secure with the original four (4) screws.
Length of warranty will vary depending on model. See warranty card for specific details. If you have any questions concerning your activTek INDUCT 5000/INDUCT 10000, please see your local activTek Distributor. for help, visit www.activTek.net.