activTek INDUCT 5000 Manual

Electronic air purification system
Hide thumbs Also See for INDUCT 5000:

Advertisement

CE DECLARATION OF CONFORMITY
We, on behalf of the manufacture:
Declare under our sole responsibility, that the Electronic Air Purification System
Model: activTek INDUCT 5000 and activTek INDUCT 10000
to which this declaration relates, conforms with the following standards:
EN55015-1:2005 EMC Requirements for Household Appliances and Similar
Apparatus-Emissions
EN61010-1:2001 Safety of Electrical Equipment for Measurement, Control and
Laboratory Use-General Requirements
By conformance with the standards referenced, the product meets the provisions of
the EU Directives listed below:
Low Voltage Directive
EMC Directive
Authorized by:
Representative:
Title:
Company:
Date:
activTek INDUCT 5000
73/23/EEC as amended by
98/68/EEC
89/336/EEC as amended by
92/31/EED and 93/68/EEC
_____________________
Robert S Vincent
General Manager
activTek Environmental
10 Dunley Hill Cort
Ranmore, Dorking RH5 6SX
27th March 2006
, activTek INDUCT 10000
, ActivePure
310 T. Elmer Cox Drive
Greeneville, TN 37743
U.S.A.
, are Trademarked by activTek
Environmental.
65-00239-001R
ID_5K-10K_OM_ 65-00239-001R _0707

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INDUCT 5000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for activTek INDUCT 5000

  • Page 1 Greeneville, TN 37743 U.S.A. Declare under our sole responsibility, that the Electronic Air Purification System Model: activTek INDUCT 5000 and activTek INDUCT 10000 to which this declaration relates, conforms with the following standards: EN55015-1:2005 EMC Requirements for Household Appliances and Similar...
  • Page 2 ELECTRoNIC AIR PURIfICATIoN SySTEM activTek Environmental 310 T. Elmer Cox Drive Greeneville, TN 37743 CAUTION: Read manual carefully for proper procedures and operation.
  • Page 3: Table Of Contents

    Please record the name and phone of your activTek Distributor: Name ____________________________________________________________________ Phone ____________________________________________________________________ Please record the serial number of your activTek INDUCT 5000/INDUCT 10000 by activTek: Serial # ___________________________________________________________________ This owner's manual covers both the activTek INDUCT 5000 single commercial probe unit and the activTek INDUCT 10000 dual commercial probe unit.
  • Page 4: Features

    The ActivePure Cell (Advanced oxidation System) is designed to reduce odors, air pollutants, and other contaminants through a patent pending ActivePure process. When the activTek INDUCT system is in operation, the ActivePure Cell uses an Advanced oxidation Process to reduce airborne contaminants. The ActivePure Cell also has the added benefit of producing safe, low levels of ozone as a by-product of the ActivePure reaction.
  • Page 5: Periodic Maintenance

    PERIODIC MAINTENANCE The only periodic maintenance required for the activTek INDUCT 5000/INDUCT 10000 is replacement of the ActivePure Cell(s). operation of the ActivePure Cell(s) is indicated by the small indicator lamp(s) located on the bottom of the ballast cover (see diagram below).
  • Page 6: Installation Requirements

    2. The ductwork around the installation area should be clean and dry to insure proper connection. 3. Depending on model, one opening (activTek INDUCT 5000) or two openings (activTek INDUCT 10000) approximately 4” (four inches) (10.16 cm) in diameter will need to be cut into the existing duct work to install the unit properly.
  • Page 7: Installing The Unit

    It is recommended for maximum effectiveness that the unit be placed as close to the air handler as possible. PLEASE NOTE: The illustrations are shown installing an activTek INDUCT 10000. procedures shown in this manual apply to both units, unless otherwise indicated.
  • Page 9 INDUCT 10000 - CELL'S hOLE PLACEMENT TEMPLATE...
  • Page 11 INDUCT 5000 - CELL hOLE PLACEMENT TEMPLATE...
  • Page 12: Wiring The Unit

    WARNING: Hard wiring unit into HVAC system should be done by a licensed HVAC installer or qualified electrical contractor only. 1. Connect wires coming from the activTek INDUCT 5000/INDUCT 10000 unit to the fan relay as follows: All units come standard with a blunt cord.
  • Page 13: Replacing The Activepure Cell

    THE INDICATOR LAMPS ON THE BOTTOM OF THE uNIT HOuSING ONLY. Note: Disconnect power at the breaker or fuse panel before servicing unit. 1. Disconnect power at the breaker or 2. Remove the activTek INDUCT ballast fuse panel before servicing unit. assembly by removing the four (4) wing nuts and sliding the unit out.
  • Page 14: Replacing The Ballast

    (4) screws then removing cover. 3. Remove the two (2) nuts on the 4. Remove the wires (activTek top and bottom side of the ballast INDUCT 10000 - 8 wires, INDUCT to pull ballast from assembly.
  • Page 15: Replacement Parts List

    REPLACING ThE BALLAST (CONTINUED) 5. Place new ballast into original 6. Return wiring to its original location and fasten the two (2) locations on the ballast. locking nuts into place. 7. Replace cover and secure with the original four (4) screws.
  • Page 16: Disposing Of The Activepure Cell

    Length of warranty will vary depending on model. See warranty card for specific details. If you have any questions concerning your activTek INDUCT 5000/INDUCT 10000, please see your local activTek Distributor. for help, visit www.activTek.net.

This manual is also suitable for:

Induct 10000

Table of Contents